9.6.13 Trip (ID=1280)
This parameter enables the ability to detect START and STOP of the trip.
Possible values are
: 0 – disabled (default), 1 – standard, 2 – private/business.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
9.6.14 Start Speed (ID=1281)
This parameter represents speed, which is detected as minimum speed to
indicate TRIP START and generate event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
-
U8
9.6.15 Ignition Off Timeout (ID=1282)
This parameter represents timeout to wait if the ignition is off in order to
detect TRIP STOP and generate an event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
65535
-
Ignition Source (ID=1003)
Mode Switch Source
(ID=1002) Trip (ID=1280)
U16