Technical documentation

AIR WATER HEATERS IN STEEL CASING S-3S SERIES

MODELS:

 S1-3S
 S2-3S

S3-3S
S4-3S

Содержание S1-3S

Страница 1: ...Technical documentation AIR WATER HEATERS IN STEEL CASING S 3S SERIES MODELS S1 3S S2 3S S3 3S S4 3S ...

Страница 2: ... 3PACKAGECONTENT heater operationandmaintenancemanualandwarrantycard 1 4USE Heating devices Reventon Group S series are used to heat spaces such as production halls warehouses commercial room service spaces garages workshops greenhouses tents shops malls shopping malls etc However heating devices should not be used in corrosive environments for aluminum copper and steel as well as in highly dusty ...

Страница 3: ... 0 73 9 8 7 6 5 S2 3S 3 stage 2000 m3 h 0 5 10 15 20 20 1 18 4 16 7 15 0 13 4 28 0 31 0 34 0 37 0 39 9 0 88 0 81 0 73 0 66 0 59 7 6 5 4 3 80 60 90 70 40 30 120 90 S1 3S 3 stage 1400 m h S1 3S 3 stage 1400 m h S1 3S 3 stage 1400 m3 h S1 3S 3 stage 1400 m3 h S2 3S 3 stage 2000 m3 h S2 3S 3 stage 2000 m3 h for parameters 90 70 C and 0 C inlet air temperature max 120 90 C 0 C inlet air temperature III...

Страница 4: ... h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the heat exchanger kPa Parameters Supply return water temperature C Dry bulb air inlet temperature C Heating capacity kW Dry bulb air outlet temperature C Water flow m h Pressure drop in the he...

Страница 5: ...valveonthesupplyandreturnpipesofthedevice installationhastobesecuredagainstexcessiveincreaseofpressure it is recommended to check the leak tightness of the hydraulic system before plugging theelectricsupply 4 2 CONNECTIONOFTHEDEIVCETOTHEELECTRICALSYSTEM all works concerning electrical installation should be made by the qualified personnel who possess required authorizations to install electrical e...

Страница 6: ...NTC 10K Communication RS485 Dimensions 86 x 86 x 13 3 mm Weight 270 g Degree of protection housing IP 20 Degree of protection external sensor IP 68 Programmable controller HMI 3 stagespeedcontrollerwiththermostatHC 3S FanspeedcontrollerHC Two wayvalvewithactuator ManualthermostatHC designed to change the single phase fan s speed voltage controlled in industrial supply and heating systems It is ava...

Страница 7: ...e with actuator HC 6 Fan speed controller HC 7 Manual thermostat HC 8 Programmable controller HMI 9 Relay module RM 16A 10 External temperature sensor main switch and safety fuses are not included in the set Model 7 5 5 3 12 8 8 5 17 12 12 8 S1 3S S2 3S S3 3S S4 3S 7 5 5 3 12 8 8 5 RM 16 A 35 24 24 16 40 27 27 19 3 2 2 1 COOPERATION OF CONTROLLERS WITH EQUIPEMENT HC 3 A HC 5 A HC 7 A HMI HC3S HC 1...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ...elimit VII Warranty does not cover the parts of the device subject to normal maintenanceandthefollowingcases a mechanicaldamageoftheproduct b defectsanddamagesthrough improperstorageortransport improper or non compliant use and maintenance i e inconsistent withthemanual using the device in the improper conditions too high humidity too high ortoolowtemperature impactofthesurrounding sunetc unauthor...

Страница 15: ...Warranty card Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland ...

Страница 16: ...Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland www reventongroup eu ...

Отзывы: