SYSTEM CONFIGURATION
SeaBat 7125 SV2 Operator‟s Manual
Page 37
July 25, 2011
Version 3
Selecting Details from the Normalization menu will display the time and date
of the last normalization.
The current channel normalization status of the system appears on the sonar image
control portion of the Primary Display (see also
section 5.3.5 Normalization Indicator
4.5 I/O Module Configuration
The I/O Module Setup tab is the primary means of configuring data flow into the SeaBat
from RS-232 devices attached to the system (such as online SV probe and/or clock).
Configuration through this interface sets up the I/O module installed on the transceiver.
The data acquired by the I/O module is routed to the SeaBat in real time to allow for
accurate time stamping and beamforming.
For instructions on how to monitor the I/O module devices, see
section 4.5.3 below.
For instructions on how to install the I/O module devices, see a
ppendix C.4 Auxiliary