F lo w C o n  S e n s o r  /  S e n s o r  H E

|

0,0

1,0

2,0

3,0

4,0

5,0

6,0

7,0

8,0

9,0

10,0

0

200

400

600

800

1000

1200

0

9,8

19,6

29,4

39,2

49

58,8

68,6

78,4

88,2

98

FlowCon Sensor / Sensor HE

Grundfos Solar PM 15-85

Wilo ST 15/6

Pump characteristic / pressure loss characteristic 

F lo w C o n  S e n s o r  /  S e n s o r  H E

flow rate [l/h]

pr

essur

e loss [kPa]

pr

essur

e [mWS]

The installation and commissioning of the solar station as 
well as the connection of electrical components requires 
technical knowledge commensurate with a recognised 
vocational qualification as a fitter for plumbing, heating and 
air conditioning technology, or a profession requiring a com-
parable level of knowledge. The following must be observed 
during installation and commissioning:
• the relevant regional and national regulations
• the accident prevention regulations of the trade association
• the technical and safety instructions of these instructions

Safety instructions

WARNING: Risk of scalding
There is a danger of steam emission with safety val-
ves. Therefore a discharge pipe must be connected 
to the ¾“ internal thread of the safety assembly. 
Please observe the enclosed instructions regarding 
the safety valve when doing this.

Attention: Damage to property
The group of fittings must be installed with suffi-
cient spacing to the collectors because tempera-
tures in the vicinity of the collectors can be very 
high.  An intermediate vessel may be necessary for 
installation in the attic.

Attention: Damage to property
It is imperative that you make sure the EPDM 
sealing elements of the solar station do not come 
into contact with substances containing mineral oil. 
Mineral oil products cause lasting damage to the 
material, whereby its sealant properties are lost. 
If necessary, ask the manufacturer whether the 
solar fluid, fats or installation aids contain mineral 
oils.
The manufacturer does not assume liability nor 
provide warranty for damage to property resulting 
from sealants damaged in this way.

Содержание FlowCon Sensor HE

Страница 1: ...ns o r H E Installation Operation Commissioning F lo w C o n S e n s o r H E www resol de Manual 48004841 48004841 EN Thank you for buying this RESOL product Please read this manual carefully to get...

Страница 2: ...ignal words describe the danger that may occur when it is not avoided WARNING means that injury possibly life threatening injury can occur ATTENTION means that damage to the appliance can occur Dispos...

Страница 3: ...valve to prevent inadmissible overpressure High efficiency pump F lo w C o n S e n s o r H E only In order to optimise the time frame the algorithm takes a range of parameters into account e g the ti...

Страница 4: ...ation 417 mm Width with insulation 374 mm Depth with insulation 179 mm Distance centre 160 mm Distance axis wall 55 mm Pipe connections IT Connection to expansion vessel 3 4 AG flat sealing Outlet saf...

Страница 5: ...hnical and safety instructions of these instructions Safety instructions WARNING Risk of scalding There is a danger of steam emission with safety val ves Therefore a discharge pipe must be connected t...

Страница 6: ...n demounting the clips c have to be removed 2 Mounting the station WARNING Scald danger Danger of severe application damage Flushing and or filling the system on a very sunny day can lead to a sudden...

Страница 7: ...rStopp until the discharged solar fluid is free of air bubbles Connect the expansion vessel to the solar thermal system Close the drain valve 5 of the flushing and filling unit with the filling pump r...

Страница 8: ...after bleeding and if neces sary increase it to the specified operating pressure 4 AirStopp Bleeding the solar thermal system directly after commissioning After commissioning bleed the solar thermal s...

Страница 9: ...Please pay attention to the following steps Switch off the system disconnect plug from the mains Remove the front half of the insulation Unscrew the cross recessed screw of the front cover and remove...

Страница 10: ...ptional Outputs 1 semiconductor relay 1 PWM signal output D e lt a S o l Sensor HE only Bus RESOLVBus Power supply 100 240V Standby power consumption 0 63 W Max power consumption 1 08 W Mode of operat...

Страница 11: ...used for scrolling downwards and reducing values Button 3 is used for selection of the menu items and for confirmation upwards PE R1 Mains 11 12 13 14 15 16 17 N L N L Protective earth Collector cir c...

Страница 12: ...rs upon first commissioning Only if the commis sioning assistant has been successfully completed will the controller commence normal operation and the menu will become accessible The commissioning ass...

Страница 13: ...45 60 75 or 90 Due to the generous tole rance of the control algorithm an adjustment by approxi mate is fully sufficient The figure to the left may be used for support when trying to determine the til...

Страница 14: ...the heat exchanger As soon as Volume HX has been entered and confirmed the commissioning assistant can be completed and exited see below If Automatic is selected the controller adapts the ne cessary v...

Страница 15: ...Min and confirm by pressing button 3 again In the menu line below Relay mode the adjustment channel Min speed appears in the line below that the current flow rate is shown Select Min speed Adjust the...

Страница 16: ...ncrease during three or more consecutive nights System display For detailed information about the system display see chap 14 on pg 20 of this manual Temp Defect Indication of the temperature resp of a...

Страница 17: ...d at the corresponding terminal short Short circuit at the corresponding sensor Balance values Max T Flow Highest measured flow temperature since commissioning or last reset Max T Return Highest measu...

Страница 18: ...at exchanger and pump station 0 50 m 3 m Volume CF Volume of the collector field 0 0 99 0 l 4 0 l Volume HX Volume of the heat exchanger 0 0 99 0 l 9 0 l Country parameters Select country Location of...

Страница 19: ...adjusted value will not be stored in that case Selecting a function or option Select a function or option by pressing buttons 1 or 2 Briefly press button 3 Select Yes to activate resp No to deactivat...

Страница 20: ...warning messages see chapter 16 Messages Operational status Outside the testing time frame the controller is in standby phase In the system display and the status menu the remai ning time until the n...

Страница 21: ...he minimum value again the overrun stops right away and the solar loading is continued If the DT remains insufficiently high until the end of the circulation a pause is run In the system display and t...

Страница 22: ...days Display of operating days since commissioning or last reset 2 4 bar Max pressure 1 5 bar Min pressure 94 C Max flow temp 52 C Max return temp 167 Operating days 16372 kWh Heat qty 1075 h Operatin...

Страница 23: ...ues by pressing buttons 1 and 2 Briefly press button 3 to reset the value The balancing of the value restarts at zero Resetting balance values The status menu shows the current values for Status Flow...

Страница 24: ...s not have a store sensor Tstmax is considered as exceeded if the adjusted temperature plus 5 K is measured at the return sensor The current time date and the menu language will usually have been adju...

Страница 25: ...a instead of a If the menu line is selected again the collapsible submenu closes again Thus it is possible to keep the viewable menu range uncomplicated and well arranged The following submenus are a...

Страница 26: ...le if Readiness is activa ted If this function is activated the store will be cooled down via the collector field in the case that solar loading has taken place beyond Tstmax due to the readiness func...

Страница 27: ...temperature The adjustment channels T flowset and Rise appear in the next menu lines The value T flowset determines at which flow temperature the pump speed is increased for the first time The value R...

Страница 28: ...and pump station Diameter of the pipes between heat exchanger and pump station Length of the pipes between collector and pump station Enter the single length of the pipes flow and return do not have...

Страница 29: ...ies Offset to UTC Universal Time Coordinated formerly GMT Greenwich Mean Time Daylight savings time option upon activation the control ler automatically adjusts its internal clock to the European dayl...

Страница 30: ...the switch off threshold Off at Factory setting 1 0 bar Leakage Options Yes No Factory setting Yes On at Adjustment range 0 3 6 0 bar Factory setting 0 7 bar Off at Adjustment range 0 3 6 0 bar Factor...

Страница 31: ...s the fault condition has been eliminated the message will be automatically acknowledged and disappear except for the Flow rate message see ch 16 1 16 1 Permanent monitoring functions The permanent mo...

Страница 32: ...n and switch off thresholds can be adjusted as well DT monitoring Message DT too high The DT monitoring function is deactivated by default but can be activated by the user The switch on switch off thr...

Страница 33: ...essure falls below the switch on threshold On at System operation is inhibited As soon as the pressure ex ceeds the switch off threshold Off at again the message disappears and system operation recomm...

Страница 34: ...ured by these sensors will be displayed for informa tion purpose only and will not be involved in the control algorithm S1 Temp Sensor Pt1000 L 17 16 15 13 12 11 T4A 1 1 A 100 240 V R1 N DeltaSol Sens...

Страница 35: ...u 30 G geographical coordinates 29 H heat quantity measurement 27 I identification status 20 info area 20 inhibition status 21 initial commissioning 11 L language selection 12 loading status 21 M main...

Страница 36: ...L Elektronische Regelungen GmbH This especially applies to copies translations microfilms and the storage into electronic systems Editor RESOL Elektronische Regelungen GmbH Important notice We took a...