29
|
Coll. type
Options: “Evac. tube”, “Flat-plate”
Factory setting: “Flat-plate”
Select country
Options: different countries
Factory setting: none – the country is selected during
commissioning
Country parameters
System parameters
Tilt angle
Options: 0°, 15°, 30°, 45°, 60°, 75°, 90°
Factory setting: 45°
The system parameters, except for the collector type, will
usually have been adjusted upon first commissioning. In the
case of a deviation, they can be corrected in this menu.
The country parameters will usually have been adjusted
upon first commissioning. In the case of a deviation, they
can be corrected in this menu.
Adjustment of the collector type.
Adjustment of the system location.
Adjustment of the location's latitude.
The geographical coordinates are automatically adjusted to
the selected country. A manual correction is only neces-
sary if the system location is not available in the selection
of different countries.
Adjustment of the location's longitude.
The geographical coordinates are automatically adjusted to
the selected country. A manual correction is only neces-
sary if the system location is not available in the selection
of different countries.
Offset to UTC (Universal Time Coordinated, formerly:
GMT – Greenwich Mean Time)
Daylight savings time option – upon activation, the control-
ler automatically adjusts its internal clock to the European
daylight savings time scheme. If the daylight savings time
option is deactivated, the winter time of the location
should be entered.
Adjustment of the collector tilt angle. The setting can be
made by approximation (see figure in chap. 11.2).
Adjustment of the collector orientation. The setting can
be made by approximation.
If a southern latitude is entered in the adjustment channel
“Latitude”, the adjustment range switches correspondingly
to the northern orientation scope W, NW, N, NE and E.
Longitude
Adjustment range: 180.0°E ... 180.0°W
Factory setting: depends on the country selected before
Offset to UTC
Adjustment range: -12 ... 12
Factory setting: depends on the country selected before
Dayl. sav. time
Options: “Yes”, “No”
Factory setting: “Yes”
Orientation
Adjustment range: E, SE, S, SW, W (northern hemisphere)
W, NW, N, NE, E (southern hemisphere)
Factory setting: S (southern hemisphere: N)
Latitude
Adjustment range: 90.0°S ... 90.0°N
Factory setting: depends on the country selected before
If the desired country is not listed in the selection, select
a random country on the same hemisphere and enter the
exact coordinates.
Note:
If the system is situated in a large country, enter
the exact coordinates in order to achieve maxi-
mum system efficiency.