F lo w C o n  S e n s o r  /  S e n s o r  H E

| 

16

1.8 bar

Pressure

500 l/h

Flow rate

18.4 kW

Power

System OK

P

V

Display

Description

Adjustment range

Factory setting

Info area
Status display

 

Pressure

Current system pressure at the return sensor

Power

Current power of the system

Flow  rate

Current flow rate at the flow sensor

System  ok

Everything alright – no error

In the case of an error or warning, the display illumination flashes! 
For more informationen about possible errors see chap. 16 on pg. 31 of this manual.
Other possible messages (instead of “System ok”):

T-Fl  defect

Digital flow sensor defective

T-Re  defect

Digital return sensor defective

Manual  mode

Manual mode (Relay mode on “Min.”, “Max.” or “Off”)

D

T  too  high

D

T has been larger than 50 K for 20 minutes

Overpressure

Excess pressure warning

Leakage

Low pressure warning

Flow  rate?

Flow rate warning, no flow rate has been detected 

Fl  pipe  circ.

Flow pipe circulation – significant temperature increase during three or more consecutive nights

Re  pipe  circ.

Return pipe circulation – significant temperature increase during three or more consecutive nights

System display

For detailed information about the system display see chap. 14 on pg. 20 of this manual

Temp.  /  Defect

Indication of the temperature, resp. of a defect at the corresponding sensor

Loading,  ...

Indication of the operational status above the store symbol, where applicable with a count-
down of the remaining phase runtime, see chap. 14

Balance value diagrams

Flow  temp.  today

Flow temperature curve of the current day

Ret  temp.  today

Return temperature curve of the current day

Flow  temp.  yest.

Flow temperature curve of the previous day

Ret  temp.  yest.

Return temperature curve of the previous day

Gains  in  kWh

Bar chart showing the heat gains of the last seven days

Balance value displays

Max.  pressure

Maximum system pressure

Min.  pressure

Minimum system pressure

Max.  flow  temp.

Maximum flow temperature

Max.  return  temp.

Maximum return temperature

Max.  power

Maximum power

Heat  qty.

Heat quantity cumulated since commissioning or last reset

Operating  hours  R1

Operating hours relay 1

12.   Menu structure

The controller is operated and controlled via the menu. 
During normal operation, the status is displayed.

Note:
The  displayed  values  and  options  depend  on 
the functions and only appear if these are available 
for the adjusted system parameters.

Содержание FlowCon Sensor HE

Страница 1: ...ns o r H E Installation Operation Commissioning F lo w C o n S e n s o r H E www resol de Manual 48004841 48004841 EN Thank you for buying this RESOL product Please read this manual carefully to get...

Страница 2: ...ignal words describe the danger that may occur when it is not avoided WARNING means that injury possibly life threatening injury can occur ATTENTION means that damage to the appliance can occur Dispos...

Страница 3: ...valve to prevent inadmissible overpressure High efficiency pump F lo w C o n S e n s o r H E only In order to optimise the time frame the algorithm takes a range of parameters into account e g the ti...

Страница 4: ...ation 417 mm Width with insulation 374 mm Depth with insulation 179 mm Distance centre 160 mm Distance axis wall 55 mm Pipe connections IT Connection to expansion vessel 3 4 AG flat sealing Outlet saf...

Страница 5: ...hnical and safety instructions of these instructions Safety instructions WARNING Risk of scalding There is a danger of steam emission with safety val ves Therefore a discharge pipe must be connected t...

Страница 6: ...n demounting the clips c have to be removed 2 Mounting the station WARNING Scald danger Danger of severe application damage Flushing and or filling the system on a very sunny day can lead to a sudden...

Страница 7: ...rStopp until the discharged solar fluid is free of air bubbles Connect the expansion vessel to the solar thermal system Close the drain valve 5 of the flushing and filling unit with the filling pump r...

Страница 8: ...after bleeding and if neces sary increase it to the specified operating pressure 4 AirStopp Bleeding the solar thermal system directly after commissioning After commissioning bleed the solar thermal s...

Страница 9: ...Please pay attention to the following steps Switch off the system disconnect plug from the mains Remove the front half of the insulation Unscrew the cross recessed screw of the front cover and remove...

Страница 10: ...ptional Outputs 1 semiconductor relay 1 PWM signal output D e lt a S o l Sensor HE only Bus RESOLVBus Power supply 100 240V Standby power consumption 0 63 W Max power consumption 1 08 W Mode of operat...

Страница 11: ...used for scrolling downwards and reducing values Button 3 is used for selection of the menu items and for confirmation upwards PE R1 Mains 11 12 13 14 15 16 17 N L N L Protective earth Collector cir c...

Страница 12: ...rs upon first commissioning Only if the commis sioning assistant has been successfully completed will the controller commence normal operation and the menu will become accessible The commissioning ass...

Страница 13: ...45 60 75 or 90 Due to the generous tole rance of the control algorithm an adjustment by approxi mate is fully sufficient The figure to the left may be used for support when trying to determine the til...

Страница 14: ...the heat exchanger As soon as Volume HX has been entered and confirmed the commissioning assistant can be completed and exited see below If Automatic is selected the controller adapts the ne cessary v...

Страница 15: ...Min and confirm by pressing button 3 again In the menu line below Relay mode the adjustment channel Min speed appears in the line below that the current flow rate is shown Select Min speed Adjust the...

Страница 16: ...ncrease during three or more consecutive nights System display For detailed information about the system display see chap 14 on pg 20 of this manual Temp Defect Indication of the temperature resp of a...

Страница 17: ...d at the corresponding terminal short Short circuit at the corresponding sensor Balance values Max T Flow Highest measured flow temperature since commissioning or last reset Max T Return Highest measu...

Страница 18: ...at exchanger and pump station 0 50 m 3 m Volume CF Volume of the collector field 0 0 99 0 l 4 0 l Volume HX Volume of the heat exchanger 0 0 99 0 l 9 0 l Country parameters Select country Location of...

Страница 19: ...adjusted value will not be stored in that case Selecting a function or option Select a function or option by pressing buttons 1 or 2 Briefly press button 3 Select Yes to activate resp No to deactivat...

Страница 20: ...warning messages see chapter 16 Messages Operational status Outside the testing time frame the controller is in standby phase In the system display and the status menu the remai ning time until the n...

Страница 21: ...he minimum value again the overrun stops right away and the solar loading is continued If the DT remains insufficiently high until the end of the circulation a pause is run In the system display and t...

Страница 22: ...days Display of operating days since commissioning or last reset 2 4 bar Max pressure 1 5 bar Min pressure 94 C Max flow temp 52 C Max return temp 167 Operating days 16372 kWh Heat qty 1075 h Operatin...

Страница 23: ...ues by pressing buttons 1 and 2 Briefly press button 3 to reset the value The balancing of the value restarts at zero Resetting balance values The status menu shows the current values for Status Flow...

Страница 24: ...s not have a store sensor Tstmax is considered as exceeded if the adjusted temperature plus 5 K is measured at the return sensor The current time date and the menu language will usually have been adju...

Страница 25: ...a instead of a If the menu line is selected again the collapsible submenu closes again Thus it is possible to keep the viewable menu range uncomplicated and well arranged The following submenus are a...

Страница 26: ...le if Readiness is activa ted If this function is activated the store will be cooled down via the collector field in the case that solar loading has taken place beyond Tstmax due to the readiness func...

Страница 27: ...temperature The adjustment channels T flowset and Rise appear in the next menu lines The value T flowset determines at which flow temperature the pump speed is increased for the first time The value R...

Страница 28: ...and pump station Diameter of the pipes between heat exchanger and pump station Length of the pipes between collector and pump station Enter the single length of the pipes flow and return do not have...

Страница 29: ...ies Offset to UTC Universal Time Coordinated formerly GMT Greenwich Mean Time Daylight savings time option upon activation the control ler automatically adjusts its internal clock to the European dayl...

Страница 30: ...the switch off threshold Off at Factory setting 1 0 bar Leakage Options Yes No Factory setting Yes On at Adjustment range 0 3 6 0 bar Factory setting 0 7 bar Off at Adjustment range 0 3 6 0 bar Factor...

Страница 31: ...s the fault condition has been eliminated the message will be automatically acknowledged and disappear except for the Flow rate message see ch 16 1 16 1 Permanent monitoring functions The permanent mo...

Страница 32: ...n and switch off thresholds can be adjusted as well DT monitoring Message DT too high The DT monitoring function is deactivated by default but can be activated by the user The switch on switch off thr...

Страница 33: ...essure falls below the switch on threshold On at System operation is inhibited As soon as the pressure ex ceeds the switch off threshold Off at again the message disappears and system operation recomm...

Страница 34: ...ured by these sensors will be displayed for informa tion purpose only and will not be involved in the control algorithm S1 Temp Sensor Pt1000 L 17 16 15 13 12 11 T4A 1 1 A 100 240 V R1 N DeltaSol Sens...

Страница 35: ...u 30 G geographical coordinates 29 H heat quantity measurement 27 I identification status 20 info area 20 inhibition status 21 initial commissioning 11 L language selection 12 loading status 21 M main...

Страница 36: ...L Elektronische Regelungen GmbH This especially applies to copies translations microfilms and the storage into electronic systems Editor RESOL Elektronische Regelungen GmbH Important notice We took a...

Отзывы: