Mounting

Connection

Operation

Examples

Thanks for buying a RESOL.
Read this manual carefully to get the best performance from this unit.

*48002780*

48002780

Содержание 115 313 20

Страница 1: ...ol ol ol ol B www resol de RESOL D D D D DeltaS eltaS eltaS eltaS eltaSol ol ol ol ol B Mounting Connection Operation Examples Thanks for buying a RESOL Read this manual carefully to get the best per...

Страница 2: ...a lot of care over the texts and drawings of this manual and to the best of our knowledge and consent As faults can never be excluded please note Your own calculations and plans under consideration of...

Страница 3: ...elow the display The newly developed combined LC display enables an intuitive and re liable controller configuration as well as a comprehensive visualisation of the system status Collector cooling and...

Страница 4: ...aSol B 1 full kit incl 3 Temperature sensors Pt1000 1 x FKP6 2 x FRP6 115 313 80 Version 52 02 1 Semiconductor relay Speed control RESOL DeltaSol DeltaSol DeltaSol DeltaSol DeltaSol B 2 115 313 20 RES...

Страница 5: ...mm afterwards put the lower dowel 4 Fasten the housing at the underground 1 2 Electrical wiring The power supply to the controller must only be made by an external power supply switch last step of ins...

Страница 6: ...r any pipe diameter cpl with fastening collar FK 21 or FR 21 Ensure good thermal contact of the sensor with the pipe work by cleaning the contact area and by applying heat conduction paste between sen...

Страница 7: ...2 HO Hours of Operation solar operating hours only PG 51 02 and 53 02 DO Temperature Difference On starting temperature difference DF Temperature Difference OfF switch off temperature difference SX St...

Страница 8: ...to realize a pure maximum temperature limitation and to deactivate the recooling and or collector cooling function FN 1 must be adjusted 3 2 1 Indication channelTC The indication channel TC indicates...

Страница 9: ...e maximum collector temperature is exceeded the operating control lamp flashes green 3 2 11Recooling function Recooling FN 2 FN 2 FN 2 FN 2 FN 2 If the adjusted maximum store temperature S X S X S X S...

Страница 10: ...control lamp flashes red or green depending on operation status Automatic operation MM ModeManual for PG 51 02 and PG 52 02 Manual operating mode 0 control lamp flashes red green Relay 1 off 1 control...

Страница 11: ...re is a malfunction due to a sensor defect the operating control lamp flashes red and the symbol is shown on the display T3 is not affected An error code for the concerned sensor is shown on the displ...

Страница 12: ...erature 6 2 Solar system with 1 collector 1 store and after heating only PG 53 02 54 02 Solar irradiation transfers heat which is made utilizable by the heat exchanger of the store 4 via collector 2 t...

Страница 13: ...heating support The controller 1 compares the temperatures measured by sensor S1 in the boiler or chimney boiler 2 with the temperature measured by sensor S2 in the store 3 If the measured temperatur...

Страница 14: ...e the pump is again deactivated The 3rd temperature sensor S3 is an additional sensor for measuring purpose e g for measuring the upper store temperature 6 6 Swimming pool solar system The controller...

Страница 15: ...erature TO and the thermostat switch off temperature TF must be adjusted in the adjustment channels Depending on the adjustment the thermostat function works in after heating or cooling operation to 4...

Страница 16: ...n pmd RESOL Elektronische Regelungen GmbH Heiskampstra e 10 D 45527 Hattingen Tel 49 0 23 24 96 48 0 Fax 49 0 23 24 96 48 55 www resol de info resol de Your wholesaler Notes Design and specifications...

Отзывы: