1.    Overview 

RP-1450FC/FT  is a PCI Fast Ethernet Board that fully complies with all 
IEEE 802.3u and 100Base-FX standards. Two LED indicators 
(LINK/ACT, FDX) on the bracket will help oversee the network/board 
link, activities, collision and full-duplex status. 

2.    Checklist 

Before you start installing the RP-1450FC/FT, verify that the package 
contains the following items: 

 

RP-1450FC/FT Board 

 

LAN Driver Diskette 

 

This User's Manual 

Please notify your sales representative immediately if any of the 
aforementioned items is missing or damaged. 

 

 

 
 
 
 

 
3.    RP-1450FC/FT PCI Configuration 

For motherboards with automatic PCI configuration:  

 

No specific setup is needed 

 

You can  enter the system BIOS setup menu to view or specify the 
interrupt line of the PCI slots 

For motherboards with bus master & interrupt jumpers: 

 

Enable bus master operation in a selected PCI slot and select

 

an 

interrupt (IRQ) level using the appropriate motherboard

 

jumper 

 

Enable I/O on the RP-1450FC/FT PCI slot 

 

4.    PCI Bus System & Configuration 

 

Ensure that the PCI machine does support master slots, INT multiple 
sharing and timing compatibility. 
Do not install FE-1450 FX in PCI slave slots. Please refer to your PCI 
system manual and select the appropriate configuration settings. 

 

When installing multiple RP-1450FC/FT 

boards at the 

server station, you should correctly configure the 
IRQ settings of the PCI slot. Up to four RP-1450FC/FT 
boards can be installed in a PCI file server running 
NetWare system. The RP-1450FC/FT 

server boards 

share the same interrupt line with the driver 
supporting multiple INT services at a time. Each 
RP-1450FC/FT's IRQ should not conflict with 

 

other boards. 

 

Operation in full or half-duplex (

Default

) mode is configured by LAN 

driver options. The operating mode should match the remote link 
device’s working status. 

 

You must use 

EMM386

 version 

4.49

 or 

higher

, and install both 

DOS 

& EMM386

 that came from the same DOS package to avoid software 

problems. 

 

5.    Diagnostic LEDs & Boot ROM 

The LINK/ACT LED lights when fiber cable connection is good and 
blinks to indicate the activity. Collision and full-duplex LED report the 
board’s operating status.

 

To add the Remote Boot feature to a workstation, you can insert the Boot 
ROM into the socket (See Fig.1).  

 

6.    Network Connection 

100Base-FX network allows 512-bit time delay between any two node 
stations in a collision domain. The Fiber cable with 
devices’ bit-time delay (round trip) is as below: 

 

 
100Base-FX 

DTE

DTE

 

Class II 

Hub

 

Fiber 

Cable

 

100 

92 

1.0/m 

 

The overall bit-time of Fiber wires and devices must be within 512 bit in a 
segment. You may use Switching Hub to break up collision domain and 
extend the cabling distance. 

 

Fiber Cable

(multi-mode)

 Limitations: 

 Half-duplex Class II Hub 

 Node to Node

 

   205m

 

 Node to Hub

 

   100m

 

 Hub to Hub

 

      5m 

 

 Half-duplex Switching Hub 

 Node to Node

 

   412m

 

 Node to Hub

 

   412m

 

 Hub to Hub

 

   412m

 

 Full-duplex Switching Hub 

 Node to Node

 

    2Km

 

 Node to Hub

 

    2Km

 

 Hub to Hub

 

    2Km

 

 

7.  Technical Specifications 

 

Standard :

 IEEE 802.3u Fast Ethernet 100Base-FX 

 

Data Transfer Mode / Speed:  

 

PCI bus master 

 

Full or half-duplex(

Default

) mode 

 

100Mbps speed 

 

LED Indicators: 

LINK/ACT

FDX on the bracket

 

 

Power Requirement      : 

1.0A @+5V  

 

Ambient Temperature  :  

0 to 50

°

 

Humidity : 

 5% to 90% 

 

PCB  Dimensions: 

 22.5(H) 

×

 80(W) 

×

138(D) mm 

 

Complies with FCC Part 15 Class A and CE Mark

 

Note: For connecting this device to Router, Bridge or 
          Switch, please refer to the corresponding device's  
          Technical Manual.

 

 

(41RP-1450FC-000) 

 
 
 
 
 

Fig. 1  Diagnostic LEDs and Boot ROM Socket 

 

   Notch

 

    Boot Rom Socket 

Fig. 1  Diagnostic LEDs and Boot ROM Socket 

 