Colour therapy

 (optional)

If colour therapy is integrated in the steam bath, a red, blue, yellow and green 
lamp is installed for colour therapy in addition to the white steam bath lighting.

The colour lamps for colour therapy can be controlled manually or using a 
programme.

The lamp functions can also be used when the

 steam bath is off.

Allocation of the keys to the lamp colours

Key 

   

Yellow

Key 

   

Red

Key 

   

Blue

Key 

   

Green

Key 

   

White

Manual switching on of the individual lamps

By briefly pressing the keys  

  or 

 the lamp allocated to the respec-

tive key is either switched on or off. The respective key is illuminated when the 
lamp is switched on.

Manual brightness setting

Repressing the corresponding key for the lamp which is switched on 

  

or 

 will activate the brightness setting mod. The respective key flashes.

You can then set the brightness of the corresponding lamp using the 

 and 

 

keys.

If the  

 key is pressed longer whilst the steam bath lighting is on,  

P0 

appears 

on the display and all the lamps in the steam bath are switched off.

Calling up the colour therapy programmes

A total of six programmes are available. 

If the 

 key is pressed longer whilst the steam bath lighting is off,  

P1 

appears on 

the display and you can select a colour therapy programme.

To select a programme, now briefly press the 

 several times consecutively until 

the desired programme number is shown on the display.

The programme starts automatically after a few seconds and the display swit-
ches back to the initial status.

Содержание Vision 2000

Страница 1: ...e that you observe the care instructions Repabad cannot be held liable for da mages caused by inappropriate use BEDDBV2000 1 E 05 2010 repa BAD GmbH Operating instructions for steam baths and steam bath technology with generator DE 510 Star DE 3000 E R DE 4000 E R DE 1005 DE 1050 Vision 2000 sensor ...

Страница 2: ...ddition of scents 8 Aromatherapy optional 8 Colour therapy optional 9 Mist nozzles optional 11 MP3 docking station optional 11 Thermostat control if installed in the panel 11 Servicing 12 Exchanging the scent 12 Changing the illuminants 12 Decalcifying the steam generator 12 Determination of the water hardness 13 Setting the water hardness range 13 Anti lime management ALM and decalcification prog...

Страница 3: ...hol consumption or directly after eating This could burden the cardiovascular system You can only use the repaBAD DD 1000 liquid aromas Other liquid aro mas may destroy the steam bath system The steam bath steam generator must be decalcified The decalcifying cycle can vary according to the respective existing water hardness Only use repaBAD decalcifying agents art no EK 500 If other agents are use...

Страница 4: ...ge 3 If a function is selected by pressing a key this key is illuminated as long as the function is active Standard functions 38 0 C Display the display of all functions Keys for setting all functions Switching the steam bath on and off Setting the water hardness range Displaying and setting the temperature Displaying and setting the time Displaying and setting the time Displaying and setting the ...

Страница 5: ...te steam bath lighting on and off and dimming it Starting the colour therapy programmes Mist nozzles optional please refer to page 11 Switches the mist nozzles on The key is illuminated when the mist noz zles are switched on MP3 docking station optional please refer to page 11 Volume adjustment for the MP3 player switched on ...

Страница 6: ... on Press the key once to show the steam bath temperature on the display The key is illuminated whilst the temperature is displayed Setting the steam cubicle target temperature Press the key longer approx 2 seconds to switch over to temperature set ting mode The key flashes The set target temperature is then shown on the display The target temperature can be set as desired using the and keys Press...

Страница 7: ...od remains saved If the timer period expires and lighting is switched on also colour therapy the white steam bath lighting automatically illuminates for a further 3 minutes Displaying setting the time Displaying the time When the steam bath is switched on briefly press the key once to show the time on the display The key is illuminated whilst the time is displayed When the steam bath is switched o...

Страница 8: ...apy optional For aromatherapy dosed scents are added to the steam Up to 2 scents can be optionally selected Switching on the aromatherapy only for a steam bath which is switched on Briefly press the or key to switch the mixing of the respective scent on or off The corresponding or key illuminates if addition of scent is activated Setting the intensity of the aromatherapy Press the or key longer ap...

Страница 9: ...al brightness setting Repressing the corresponding key for the lamp which is switched on or will activate the brightness setting mod The respective key flashes You can then set the brightness of the corresponding lamp using the and keys If the key is pressed longer whilst the steam bath lighting is on P0 appears on the display and all the lamps in the steam bath are switched off Calling up the col...

Страница 10: ...ces bet ween the elements fire and water which are embodied by red and blue The complementary colour of yellow at the end of the programme ensures equilibrium reinforcing the special effectiveness of this programme P3 Power programme The energy colour red dominates in this programme augmented by yellow Green light moderates the strong activating power of the red light preventing too strong an effe...

Страница 11: ... can be adjusted with the and keys The and keys must not be activated by another function The volume can also be adjusted when the steam bath is switched off Thermostat control if installed in the panel Thermostat Thermostat with a 2 way stop valve with two 2 way stop valves Two way stop valve for riser rail shower and a further load Flow rate settable by turning Scalding protection at 38 higher t...

Страница 12: ...pull out the socket of the luminaire in a straight downward movement do not twist it Exchanging luminaires Re inserting the socket At the same time ensure that the retaining clips for the luminaire are positi oned on the grooves intended for this purpose Decalcifying the steam generator Danger of chemical burn Concentrated decalcifying agents can cause chemical burn If these agents come into conta...

Страница 13: ...pressed for approx 5 seconds until H is shown on the left of the display The water hardness range currently set 1 to 4 is shown on the right of the dis play Use the and keys to set the water hardness range required Press the key again to save the changed target water hardness range or it is saved automatically after approx 5 seconds Anti lime management ALM and decalcification programmes Three hou...

Страница 14: ...alcification agent is filled and starts the decalcification period of 12 hours The remaining decalcification time is shown on the display After expiry of the decalcification period PU 2 is shown on the display The steam generator is automatically pumped empty PA 3 is shown on the display as soon as the steam generator is emptied After approx 1 minute the steam generator is automatically filled wit...

Страница 15: ...gh the filling ope ning using a funnel Unscrew the decalcification tube and screw the filler neck closed The steam bath control automatically recognises when the decalcification agent is filled and starts the decalcification period of 12 hours The remaining decalcification time is shown on the display Once the decalcification time has expired the steam generator is automatical ly rinsed with fresh...

Страница 16: ...16 Examples of individual generators Filling opening on all acrylic and aluminium panels shown using steam bath Las Vegas as an example ...

Страница 17: ...abrasive dust etc before cleaning e g by rinsing it with clear water Chemical drain cleaners may not be used Clean the steam bath with a household cleaning agent after use Use a wiper to remove all water drops on the glass cubicle Clean the acrylic parts at regular intervals with anti static acrylic and plexiglass cleaner repaBAD Spezial Reiniger special cleaner art no RR repaBAD s Care set art no...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...t be notified to the specialist fitter from whom our product was purchased specifying the data provided below Delivered on Customer s address Invoice no Reason for complaint Specialist fitter s address Fitter s stamp signature Only send the warranty card in case of a complaint BEDDBV2000 1 E 05 2010 repaBAD GmbH Technical hotline 49 0 7024 94 11 88 repaBAD GmbH Bosslerstr 13 15 D 73240 Wendlingen ...

Отзывы: