14
The steam bath must be switched off.
-
Keep the
-
key approx. 5 seconds until
CALC
is shown on the display.
The key flashes.
After approx. 10 seconds,
PU1
is shown on the display.
The steam generator is automatically pumped empty.
Once the steam generator has been pumped empty, the display will show
FlLL
and
ACld
alternately.
Unscrew the filling opening clasp on the steam generator.
-
Dissolve
-
8 tablespoons
of
repa
BAD decalcification agent (art. no. EK 500)
in
5 litres of water
in a separate container and fill through the filling opening
using a funnel.
Screw the filling opening clasp on the steam generator closed.
-
The steam bath control automatically recognises when the decalcification
agent is filled and starts the decalcification period of 12 hours. The remaining
decalcification time is shown on the display.
After expiry of the decalcification period,
PU 2
is shown on the display.
The steam generator is automatically pumped empty.
PA 3
is shown on the display, as soon as the steam generator is emptied.
After approx. 1 minute, the steam generator is automatically filled with fresh
water.
Following this, the time is again shown on the display.
Use the key to interrupt the decalcification process early. The steam gene-
rator is automatically pumped empty and re-filled with fresh water.
The stipulated steam time which is based on the water hardness area only
starts anew once decalcification has been completed (12 hours)! Time spent
on decalcifications (aborted) is not cumulated!
Steam
generator
DE 1005
Filling opening
for
decalcification
agents