REO 621103 Скачать руководство пользователя страница 1

REO-USA, Inc.
3250 North Post Road, Suite 132
Indianapolis, IN 46226
Phone (317) 899-1395

e-mail: [email protected]

Fax (317) 899-1396

web: www.reo-reo.com

P

F

Operating instructions

MFS 268XXL 16A
ID# 626887

MFS 268XL 12A
ID# 626867

Features

-Feeder operating frequency is adjustable and independent of mains frequency.
-Constant  feed  rate  ensured  by  internal  compensation,  irrespective  of  mains                       
fluctuations.
-Integrated track control via backlog sensor.
-24  V  DC  output  for  operating  an  air  valve  (IP  54  version),  and  amplitude  control 
(sensor required).
-Independent resonant frequency search possible for feeder.
-Enable input (start / stop), status relay (output active / inactive).
-Stand-alone housings (IP 54) or panel-mounted units (IP 20).

Technical  data:

Supply voltage

110 / 240 V, +/- 10%, 50/60 Hz

Output

0...100 / 0... 205 V, 3 A, 6 A, 8 A, 12A, 16A

Output frequency

5...300 Hz, (preset at  35... 140 Hz)

Enable input

Contacts or  24 V, DC

Track sensor

24 V, PNP (100 mA)

Solenoid air valve output

24 V, (150 mA)

Status output relay (ON/OFF)

Changeover contact (250 V, 1 A)

Operating temperature

0...+45 °C

Storage temperature

-10...+80 °C

Recommended fuse

3 A, 8 A, 16 A slow-blowing, Type 'D' MCB

Increase value

Decrease value

Programming mode
or Enter

Menus are used for changing settings. The different parameters are 
selected by entering a code.

All  adjustments  are  made  by  first  pressing  the  P  key,  followed  by 
selecting the menu code, using the cursor keys.

Settings

Pressing  the  cursor  key  for  a  short  time  causes  one  digit 
increase/decrease, holding down for a longer time gives changes in 
ten-digit steps.
Changed settings are saved when exiting the menu or automatically 
if a key is not pressed for 60 seconds.

Return

Display and controls

Instructions:

Enable OFF

Track full

Setpoint in %

Timer running

Stop using "0" key

Operating displays

REOVIB MFS 268

Frequency controllers for vibratory feeders 

MFS 268 IP20 16A
ID# 621103

Data is subject to change for the benefit of technical improvement.

I

0

Controller Output
ON
Controller Output
OFF

1

12_14_2005

I

0

P

F

www.reo-usa.com

 8450 E. 47th Street

All manuals and user guides at all-guides.com

all-guides.com

Содержание 621103

Страница 1: ...150 mA Status output relay ON OFF Changeover contact 250 V 1 A Operating temperature 0 45 C Storage temperature 10 80 C Recommended fuse 3 A 8 A 16 A slow blowing Type D MCB Increase value Decrease value Programming mode or Enter Menus are used for changing settings The different parameters are selected by entering a code All adjustments are made by first pressing the P key followed by selecting t...

Страница 2: ... 0 064 Save user settings 0 3 PUSH 0 143 Restore factory settings FAC 210 Restore user settings 0 3 US PA 0 210 Hide programming menus 0 I Hd C 0 117 Hide setpoint adjustment 0 I di S 0 137 Display software version 001 Settings Range Code Factory Menu settings code Input voltage too high Error messages must be cleared in Menu no C 009 by means of Cl err Possible cause Incorrect wiring possibly a d...

Страница 3: ...led operation Electrical connections must be covered Earth connections must be checked for correct function after installation Specified use The units described herein are electrical controllers for installation in industrial plants They are designed for power adjustment on vibratory feed equipment Declaration of conformity We declare that these products conform with the following standards and di...

Страница 4: ...ometer Display Sensor Feed rate Track control backlog Coarse fine control Enable Feed rate Enable Feed rate Amplitude Feed rate Setpoint Amplitude Feed rate Setpoint Feed rate Maximum Set point input Sensor input Enable input Maximum feed rate Vibrating frequency Soft start soft stop Internal using keys in touch panel External setpoint 0 10 V 0 4 20 mA Potentiometer 10 KW Track control or Coarse f...

Страница 5: ... e f t d o e r or ons n m t de c a us e t e i e of m to ns hat the f x ures a ol d r i e t orre e at on nd not fl x under vibrat on t i t re s i p ov d he c ct ori nt i a do e i Ma ua se tin of t e v br ti f quenc n l t g h i a ng re y t s p rtan t av w s t p i t sett n e g 0 ecau e up n re c ing r so an e it s os ib e tha a hig m lit de w l be in uc d v n with a l w o t ut I i im o t o h e a lo e...

Страница 6: ...tch off time delay 0 60 sec Operating mode Invert sensor function I inverted Code C 007 C 167 Track control Backlog sensor Sensor Feeder Sensor ON OFF Sensor Sensor Time delays Sensor Adjustment of the ON and OFF delays Invert sensor input Run on time for air valve output t on t off Feeder OFF Air valve OFF t on Setting the run on time for the air valve output Air valve output Feeder 0 Pulse feed ...

Страница 7: ...reviously stored under C143 Save parameter settings Select parameters 0 to 3 Saves up to 4 different parameters no 0 3 Select parameters 0 to 3 Saves up to 4 different parameters no 0 3 Code 117 Inhibit access I Hidden menus Operating mode Parameter menus cannot be accessed except for the feed rate setpoint Parameter menus can be accessed Hide programming menus 0 Setpoint access ON I Setpoint acce...

Страница 8: ... frequency range Parameters F L and F H in Menu C 040 Effective frequency range Parameter F in Menus C 008 C 096 and C 020 When operated with 230 240 V mains supply the output voltage is limited to 100 V Display shows the actual vibration frequency Setting the limits of the frequency adjustment range accessible for the user A narrow adjustment range is preferable for the automatic frequency search...

Страница 9: ...MFS 268 621605 3Amp IP 20 REOVIB MFS O I P F 9 All manuals and user guides at all guides com ...

Страница 10: ...REO USA F P O I MFS 268 626848 8Amp IP 20 10 All manuals and user guides at all guides com ...

Страница 11: ...REO USA F P O I MFS 268 621103 15Amp IP 20 11 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 12: ...V DC 4 5 E 24V 31 32 33 SW L N PE PE 26 27 28 29 10 GND USA P P P SPEED I 0 P F Track Sensor Feeder Enable Set point Accelerometer orange black red Main Input 22 23 24 25 21 MFS 268 3Amp 8Amp IP 20 Electrical Status Relay 12 All manuals and user guides at all guides com ...

Страница 13: ...IB MFS 268 USA P P P SPEED I 0 P F Track Sensor Feeder Enable Set point Accelerometer orange black red Main Input Output Screen clamb for cable from acceleration sensor Screen clamb for output cable Only use screened power output cables Only use screened control cables MFS 268 15Amp IP 20 Electrical 13 All manuals and user guides at all guides com ...

Страница 14: ...MFS 268 626848 8Amp IP 54 14 All manuals and user guides at all guides com ...

Страница 15: ...ONNECT MAIN SUPPLY BEFORE REMOVING COVER REOVIB MFS 268 REO USA F P O I Key Functions F Former Menu P Pass Accept Decrease Increase O Stop I Run www reo usa com 8 200 6 314 7 598 8 071 15 All manuals and user guides at all guides com ...

Страница 16: ... Key Functions F Former Menu P Pass Accept Decrease Increase O Stop I Run BEFORE REMOVING COVER DISCONNECT MAIN SUPPLY REOVIB MFS 268 F P O I 8 062 7 125 7 875 7 563 8 000 16 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 17: ...Input 110 240 V PE Input brown A1 blue A2 ye gn Output brown A1 blue A2 ye gn 24 V Input GND 24 V DC GND Input Track control PNP sensor X 4 screen Acceleration sensor X 40 21 22 23 Internal status relay 24 V SW 1 3 2 3 33 34 Acceleration sensor 5 6 7 1 2 3 4 8 9 24V E S A 10k 0 10V 0 4 20mA 7 8 7 8 10V 12 24V DC 4 5 External set point R 500 ohm extern Enable PNP Sensor track control 17 All manuals...

Страница 18: ...in satz 4 PE 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Buchsenein satz 4 PE L N A1 A2 1 2 3 4 1 2 3 4 Internal status relay Time out 24V Valve 24V GND Acceleration sensor External set point R 500 ohm extern Enable PNP Sensor track control Output feeder Main input 110 240 V PE Input brown A1 blue A2 ye gn Output brown A1 blue A2 ye gn 24 V Input GND 24 V DC GND Input Track control PNP sensor X 4 screen Accel...

Отзывы: