Renishaw TONiC T103x RKLC20-S Скачать руководство пользователя страница 3

TONiC RKLC20-S linear installation guide

1

Legal notices

Copyright

© 2019-2021 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in part, or transferred to any other media or 
language by any means, without the prior written permission of Renishaw.

Trade marks

RENISHAW 

®

 and the probe symbol are registered trade marks of Renishaw plc. Renishaw product 

names, designations and the mark ‘apply innovation’ are trade marks of Renishaw plc or its subsidiaries.
Loctite 

®

  is a registered trademark of the Henkel Corporation.

Other brand, product or company names are trade marks of their respective owners.

Patents

Features of Renishaw’s encoder systems and similar products are the subjects of the following patents 
and patent applications:
EP1173731

JP4750998

US6775008

CN100543424

EP1766334

JP4932706

US7659992

CN100507454

EP1766335

IN281839

JP5386081

US7550710

CN101300463

EP1946048

US7624513

JP5017275

CN101310165

US7839296

EP1957943

EP2390045

CN1314511

EP1469969

JP5002559

US8466943

US8987633

Disclaimer

WHILE CONSIDERABLE EFFORT WAS MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT 
AT PUBLICATION, ALL WARRANTIES, CONDITIONS, REPRESENTATIONS AND LIABILITY, 
HOWSOEVER ARISING, ARE EXCLUDED TO THE EXTENT PERMITTED BY LAW.
RENISHAW RESERVES THE RIGHT TO MAKE CHANGES TO THIS DOCUMENT AND TO THE 
EQUIPMENT, AND / OR SOFTWARE AND THE SPECIFICATION DESCRIBED HEREIN WITHOUT 
OBLIGATION TO PROVIDE NOTICE OF SUCH CHANGES.

Terms and conditions and warranty

Unless you and Renishaw have agreed and signed a separate written agreement, the equipment and/or 
software are sold subject to the Renishaw Standard Terms and Conditions supplied with such equipment 

and/or software, or available on request from your local Renishaw office.

Renishaw warrants its equipment and software for a limited period (as set out in the Standard Terms 

and Conditions), provided that they are installed and used exactly as defined in associated Renishaw 
documentation. You should consult these Standard Terms and Conditions to find out the full details of 

your warranty.
Equipment and/or software purchased by you from a third-party supplier is subject to separate terms and 
conditions supplied with such equipment and/or software. You should contact your third-party supplier for details.

Product compliance

Renishaw plc declares that TONiC 

 complies with the applicable standards and regulations.

A copy of the EU declaration of conformity is available from our website at 

www.renishaw.com/productcompliance

.

Compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation.

The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised 

representative could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause 
harmful interference in which case the user will be required to correct the interference at his own expense.

NOTE:

 This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with 

the unit to ensure compliance.

Further information

Further information relating to the TONiC encoder range can be found in the 

TONiC 

 encoder system

 

Data sheet (Renishaw part no. L-9517-9337). This document can be downloaded from our website at 

www.renishaw.com/tonicdownloads

 and is also available from your local Renishaw representative.

Packaging

Packaging Component

Material

ISO 11469

Recycling Guidance

Outer box

Cardboard

Not applicable

Recyclable

Polypropylene

PP

Recyclable

Inserts

Low density polyethylene foam

LDPE

Recyclable

Cardboard

Not applicable

Recyclable

Bags

High density polyethylene bag

HDPE

Recyclable

Metalised polyethylene

PE

Recyclable

REACH regulation

Information required by Article 33(1) of Regulation (EC) No. 1907/ 2006 (“REACH”) relating to products 
containing substances of very high concern (SVHCs) is available at 

www.renishaw.com/REACH

.

WEEE recycling guidelines

The use of this symbol on Renishaw products and/or accompanying documentation indicates 
that the product should not be mixed with general household waste upon disposal. It is the 
responsibility of the end user to dispose of this product at a designated collection point for waste 
electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal 
of this product will help to save valuable resources and prevent potential negative effects 
on the environment. For more information, please contact your local waste disposal service 
or Renishaw distributor.

Содержание TONiC T103x RKLC20-S

Страница 1: ...RSLM high accuracy linear encoder TONiC T103x RKLC20 S linear encoder system Installation guide M 9653 9568 02 A...

Страница 2: ...d clamps 9 Reference mark selector and limit magnet installation 10 TONiC quick start guide 11 System connection 12 Readhead mounting and alignment 13 System calibration 14 Restoring factory defaults...

Страница 3: ...iance Compliance This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept...

Страница 4: ...elf adhesive tape is on the outside of bend 95 relative humidity non condensing to IEC 60068 2 78 Humidity Storage 70 C 0 C Operating Storage and handling Readhead only Acetone CH3 COCH3 Methylated Sp...

Страница 5: ...75 Recommended mounting faces Scale thickness 0 15 including adhesive P limit magnet Reference mark selector magnet Q limit magnet Yaw tol 0 4 Rideheight 2 1 0 15 Pitch tol 1 2 off mounting holes M2...

Страница 6: ...omatic Gain Control AGC enable disable Push and hold during power Off On cycle Restore factory defaults Refer to readhead LED functionality chart for CAL LED indications Dimensions and tolerances in m...

Страница 7: ...L 40 ML L 55 with dual limits 0 5 F 0 2 100 20 A P limit magnet A 9653 0138 Dimensions as Q limit RKLC20 S scale Reference mark selector magnet A 9653 0143 Dimensions as Q limit 35 Q limit magnet A 96...

Страница 8: ...dhesive A 9531 0342 u Appropriate cleaning solvents Storage and handling page 2 u 2 M2 5 screws u Green spacer supplied with TONiC readhead Optional parts u Renishaw scale wipes A 9523 4040 u Lint fre...

Страница 9: ...ough the guillotine as shown and place guillotine press block down onto the scale Ensure the block is in the correct orientation as shown Whilst holding the block in place in a smooth motion pull down...

Страница 10: ...nted either way round to enable easiest orientation for scale installation 5 Move axis to scale start position leaving enough room for the scale to be inserted through the applicator as shown below 6...

Страница 11: ...f the end clamp 3 The end clamp features two small regions of contact adhesive These will temporarily hold the end clamp in position while the adhesive cures Remove the backing tape from either side 4...

Страница 12: ...d reference sensors Limit trigger point The limit output is nominally asserted when the readhead limit switch sensor passes the limit magnet leading edge but can trigger up to 3 mm before that edge RK...

Страница 13: ...Green interface ideally Blue Purple CALIBRATION Press and release the CAL button on the interface The CAL LED on the readhead will be single flashing Move the readhead along the scale at slow speed 1...

Страница 14: ...5 hex head screws u Taking care not to touch the pins plug the connector into the socket in the interface ensuring correct orientation as shown u Refit the cover plate ensuring the cable ferrule is lo...

Страница 15: ...flash Normal phasing Orange flash Acceptable phasing Red flash Poor phasing clean scale and recalibrate if required CAL Operating On Automatic Gain Control On Off Automatic Gain Control Off Calibratio...

Страница 16: ...ithout reference mark go to Calibration routine manual exit u If the system does not automatically enter the reference mark phasing stage no double flashing of the CAL LED the calibration of the incre...

Страница 17: ...ting that the factory defaults have been restored u Release CAL button u Check the Readhead mounting and alignment page 13 and recalibrate the system System calibration page 14 NOTE System must be re...

Страница 18: ...Black Set up VX Clear Calibrate CAL Orange Shield Inner shield Green Yellow Outer shield Outer screen Readhead output Output connector for all interfaces 15 way D type plug Becomes alarm E for Ti opt...

Страница 19: ...0 2 70 1 35 0 540 0 270 0 135 0 054 0 027 25 10 10 8 10 3 24 1 62 0 810 0 324 0 162 0 081 0 032 0 016 20 10 10 6 75 2 70 1 35 0 675 0 270 0 135 0 068 0 027 0 013 12 10 9 4 50 1 80 0 900 0 450 0 180 0...

Страница 20: ...noise issues NOTE Maximum cable length between readhead and Ti TD interface is 10 m Single ended alarm signal termination Ti options A B C D Customer electronics Interface 5 V 4k7 4k7 1k8 100R 100nF...

Страница 21: ...Active low P Q Length of limit actuator Incremental 2 channels A and B in quadrature 90 phase shifted Reference NOTE Select standard or wide reference at time of ordering to match the requirements of...

Страница 22: ...level VX is nominal 3 3 V 0 7 to 1 35 Vpp with Green LED indication readhead and 120R termination Differential signals V0 and V0 centred on 1 65 V NOTE Ti0000A00V centred on 2 5 V Output specificatio...

Страница 23: ...o IEC 60068 2 78 Sealing readhead IP40 interface IP20 Acceleration readhead Operating 500 m s2 3 axes Shock system Operating 500 m s2 11 ms sine 3 axes Vibration readhead Operating 100 m s2 55 Hz to 2...

Страница 24: ...mark directly embedded into incremental track Bi directional position repeatability Selection Single reference mark selection by selector magnet A 9653 0143 customer positioned L 100 mm Single refere...

Страница 25: ...ershire GL12 8JR United Kingdom T 44 0 1453 524524 F 44 0 1453 524901 E uk renishaw com www renishaw com For worldwide contact details visit www renishaw com contact Renishaw plc Registered in England...