TONiC RKLC20-S linear installation guide

6

  Allow scale to acclimatize to installation environment prior to installation.

  Mark out the ‘START’ and ‘FINISH’ points for the scale on the axis substrate – ensure 

that there is room for the end clamps. 

(see ‘RKLC20-S scale installation drawing’)

.

  Thoroughly clean and degrease the substrate using recommended solvents  

(see 'Storage and handling')

. Allow substrate to dry before applying scale.

  Mount the appropriate scale applicator to the readhead mounting bracket using 

M2.5 screws. Place the shim supplied with the readhead between the applicator and 
substrate to set the nominal height.  
NOTE: Scale applicator can be mounted either way round to enable easiest 
orientation for scale installation.

  Move axis to scale START position, leaving enough room for the scale to be inserted 

through the applicator.

  Begin to remove the backing paper from the scale and insert scale into the applicator 

up to the ‘START’ point (as shown).  
Ensure backing paper is routed under the splitter screw.

Scale application

There are two versions of applicator for use with RKLC20-S scale: side mounted  
(A-6547-1912) and top mounted (A-6547-1915). The side mounted version is shown below, 
but the application method is the same for both versions of the applicator.

9

  During installation ensure scale is adhered to substrate using light finger pressure.

  Slowly and smoothly move the applicator through the entire axis of travel, ensuring the 

backing paper is pulled manually from the scale and does not catch under the applicator.

 

 Remove applicator carefully. Apply firm finger pressure via a clean lint‑free cloth along the length of 

the scale after application to ensure complete adhesion.

11    Clean the scale using Renishaw scale wipes (A-9523-4040) or a clean, dry, lint-free cloth.

12    Fit end clamps see 'End clamps' below.

  Ensure that the end of the scale is in line with the ‘START’ position on the axis and 

apply finger pressure via a clean line‑free cloth to ensure scale end adheres well to 

the substrate.

10

M2.5 mounting holes

START

Splitter screw

Direction of scale application

START 

RKLC20-S

Backing tape

Splitter screw

End clamps

A-9523-4015 is an end clamp kit designed to be used with Renishaw RKLC20-S scale. Alternatively, narrow 
6 mm wide end clamps (A-9523-4027) are also available.
NOTE:  End clamps can be mounted before or after readhead installation.

Ensure that excess glue is wiped away from  
scale as it may affect the readhead signal level.

  The end clamp features two small regions of contact 

adhesive. These will temporarily hold the end clamp 
in position while the glue cures. Remove the backing 
tape from either side.

  Clean ends of scale and the area where end clamps 

are to be fitted using Renishaw scale wipes 

 

(A-9523-4040) or one of the recommended solvents 

 

(see ‘Storage and handling’)

.

  Immediately position end clamp over the end of 

the scale and push down to ensure complete 
adhesion. Allow 24 hours at 20

 °C 

for full cure.

  Thoroughly mix up a sachet of glue (A-9531-0342) 

and apply a small amount to the underside of the 
end clamp.

Содержание TONiC RKLC20-S

Страница 1: ...RSLM high accuracy linear encoder TONiC T103x RKLC20 S linear encoder system Installation guide M 9653 9568 01 A...

Страница 2: ...allation drawing 5 Scale application 6 End clamps 6 Reference mark selector and limit magnet installation 7 TONiC quick start guide 8 System connection 9 Readhead mounting and alignment 10 System cali...

Страница 3: ...n which case the user will be required to correct the interference at his own expense NOTE This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the uni...

Страница 4: ...ive tape is on the outside of bend 95 relative humidity non condensing to EN 60068 2 78 Humidity Storage 70 C 0 C Operating Storage and handling Readhead only Acetone CH3 COCH3 Methylated Spirits Chlo...

Страница 5: ...Recommended mounting faces Scale thickness 0 15 including adhesive P limit magnet Reference mark selector magnet Q limit magnet Yaw tol 0 4 Rideheight 2 1 0 15 Pitch tol 1 2 off mounting holes M2 5 t...

Страница 6: ...isable Push and hold during power Off On cycle Restore factory defaults Refer to readhead LED functionality chart for CAL LED indications 15 1 8 9 16 4 40 UNC 2 40 6 min 62 67 CAL AGC push button swit...

Страница 7: ...A 9653 0291 P limit A 9653 0292 START see page 6 Scale length L Measuring length ML L 40 ML L 55 with dual limits 0 5 F 0 2 100 20 A P limit magnet A 9653 0138 Dimensions as Q limit RKLC20 S scale Ref...

Страница 8: ...travel ensuring the backing paper is pulled manually from the scale and does not catch under the applicator Remove applicator carefully Apply firm finger pressure via a clean lint free cloth along th...

Страница 9: ...the scale NOTE Reference and limit magnets may creep when influenced by magnetic materials in close proximity In such cases they should be held in place using an additional fillet of epoxy glue or sim...

Страница 10: ...dhead Green interface ideally Blue Purple CALIBRATION Press and release the CAL button on the interface The CAL LED on the readhead will be single flashing Move the readhead along the scale at slow sp...

Страница 11: ...5 hex head screws 2 Taking care not to touch the pins plug the connector into the socket in the interface ensuring correct orientation as shown 3 Refit the cover plate ensuring the cable ferrule is lo...

Страница 12: ...iguration Also some configurations do not output overspeed alarm See product nomenclature for details Momentary status only while fault condition remains Alarm may result in axis position error re dat...

Страница 13: ...g the calibration routine Step 2 Reference mark phasing u Move the readhead back and forth over the selected reference mark until the CAL LED stops flashing and remains off The reference mark is now p...

Страница 14: ...shield on UHV cables Interface output digital Ti0004 to Ti20KD and TD4000 to TD0040 Interface Ti0004 Ti20KD TD4000 TD0040 Function Output type Signal Pin Pin Power 5 V 7 8 7 8 0 V 2 9 2 9 Incremental...

Страница 15: ...100R 100nF E Extension cable maximum 50 m dependent upon clocked output option Remote CAL operation Analogue versions only CAL 0 V All Ti TD interfaces include a push button switch to enable CAL AGC...

Страница 16: ...e high or Active low P Q Repeatability 0 1 mm Length of limit actuator Incremental 2 channels A and B in quadrature 90 phase shifted Reference NOTE Select standard or wide reference at time of orderin...

Страница 17: ...ly integrated to achieve EMC compliance In particular attention to shielding arrangements is essential RKLC20 S scale specifications Form H W 0 15 mm 6 mm including adhesive Pitch 20 m Accuracy at 20...

Страница 18: ...e marks of Renishaw plc in the United Kingdom and other countries apply innovation and names and designations of other Renishaw products and technologies are trade marks of Renishaw plc or its subsidi...

Отзывы: