Renishaw TONiC RKLC20-S Скачать руководство пользователя страница 3

TONiC RKLC20-S linear installation guide

1

The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product 
should not be mixed with general household waste upon disposal.  It is the responsibility of the end user to 
dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) 
to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent 
potential negative effects on the environment. For more information, please contact your local waste disposal 
service or Renishaw distributor.

Product compliance

Renishaw plc declares that TONiC complies with the applicable standards and regulations.  
A copy of the EC Declaration of Conformity is available on request.

FCC compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation.

The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or 

authorised representative could void the user’s authority to operate the equipment. 
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed  
and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful  
interference in which case the user will be required to correct the interference at his own expense.
NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used 
with the unit to ensure compliance.

Patents

Features of Renishaw’s encoder systems and similar products are the subjects of the following  
patents and patent applications:

EP1173731

JP4750998

US6775008

CN100543424

EP1766334

JP4932706

US7659992

CN100507454

EP1766335

IN281839

JP5386081

US7550710

CN101300463

EP1946048

US7624513

JP5017275

CN101310165

US7839296

EP1957943

EP2390045

CN1314511

EP1469969

JP5002559

US8466943

US8987633

Further information

Further information relating to the TONiC encoder range can be found in the TONiC system Data sheet  
(L-9517-9337). This can be downloaded from our website 

www.renishaw.com /encoder

 and is also available 

from your local representative. This document may not be copied or reproduced in whole or in part, or 
transferred to any other media or language, by any means without the written prior permission of Renishaw. 
The publication of material within this document does not imply freedom from the patent rights of Renishaw plc. 

The packaging of our products contains the following materials and can be recycled.

Packaging Component

Material

ISO 11469

Recycling Guidance

Outer box

Cardboard

Not applicable

Recyclable

Polypropylene

PP

Recyclable

Inserts

Low Density Polyethylene Foam

LDPE

Recyclable

Cardboard

Not applicable

Recyclable

Bags

High Density Polyethylene Bag

HDPE

Recyclable

Metalised Polyethylene

PE

Recyclable

c

REACH regulation

Information required by Article 33(1) of Regulation (EC) No. 1907/2006 (“REACH”) relating to products 

containing substances of very high concern (SVHCs) is available at: 

www.renishaw.com / REACH

Disclaimer

RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT 
IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS 
REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY 
INACCURACIES IN THIS DOCUMENT.

Содержание TONiC RKLC20-S

Страница 1: ...RSLM high accuracy linear encoder TONiC T103x RKLC20 S linear encoder system Installation guide M 9653 9568 01 A...

Страница 2: ...allation drawing 5 Scale application 6 End clamps 6 Reference mark selector and limit magnet installation 7 TONiC quick start guide 8 System connection 9 Readhead mounting and alignment 10 System cali...

Страница 3: ...n which case the user will be required to correct the interference at his own expense NOTE This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the uni...

Страница 4: ...ive tape is on the outside of bend 95 relative humidity non condensing to EN 60068 2 78 Humidity Storage 70 C 0 C Operating Storage and handling Readhead only Acetone CH3 COCH3 Methylated Spirits Chlo...

Страница 5: ...Recommended mounting faces Scale thickness 0 15 including adhesive P limit magnet Reference mark selector magnet Q limit magnet Yaw tol 0 4 Rideheight 2 1 0 15 Pitch tol 1 2 off mounting holes M2 5 t...

Страница 6: ...isable Push and hold during power Off On cycle Restore factory defaults Refer to readhead LED functionality chart for CAL LED indications 15 1 8 9 16 4 40 UNC 2 40 6 min 62 67 CAL AGC push button swit...

Страница 7: ...A 9653 0291 P limit A 9653 0292 START see page 6 Scale length L Measuring length ML L 40 ML L 55 with dual limits 0 5 F 0 2 100 20 A P limit magnet A 9653 0138 Dimensions as Q limit RKLC20 S scale Ref...

Страница 8: ...travel ensuring the backing paper is pulled manually from the scale and does not catch under the applicator Remove applicator carefully Apply firm finger pressure via a clean lint free cloth along th...

Страница 9: ...the scale NOTE Reference and limit magnets may creep when influenced by magnetic materials in close proximity In such cases they should be held in place using an additional fillet of epoxy glue or sim...

Страница 10: ...dhead Green interface ideally Blue Purple CALIBRATION Press and release the CAL button on the interface The CAL LED on the readhead will be single flashing Move the readhead along the scale at slow sp...

Страница 11: ...5 hex head screws 2 Taking care not to touch the pins plug the connector into the socket in the interface ensuring correct orientation as shown 3 Refit the cover plate ensuring the cable ferrule is lo...

Страница 12: ...iguration Also some configurations do not output overspeed alarm See product nomenclature for details Momentary status only while fault condition remains Alarm may result in axis position error re dat...

Страница 13: ...g the calibration routine Step 2 Reference mark phasing u Move the readhead back and forth over the selected reference mark until the CAL LED stops flashing and remains off The reference mark is now p...

Страница 14: ...shield on UHV cables Interface output digital Ti0004 to Ti20KD and TD4000 to TD0040 Interface Ti0004 Ti20KD TD4000 TD0040 Function Output type Signal Pin Pin Power 5 V 7 8 7 8 0 V 2 9 2 9 Incremental...

Страница 15: ...100R 100nF E Extension cable maximum 50 m dependent upon clocked output option Remote CAL operation Analogue versions only CAL 0 V All Ti TD interfaces include a push button switch to enable CAL AGC...

Страница 16: ...e high or Active low P Q Repeatability 0 1 mm Length of limit actuator Incremental 2 channels A and B in quadrature 90 phase shifted Reference NOTE Select standard or wide reference at time of orderin...

Страница 17: ...ly integrated to achieve EMC compliance In particular attention to shielding arrangements is essential RKLC20 S scale specifications Form H W 0 15 mm 6 mm including adhesive Pitch 20 m Accuracy at 20...

Страница 18: ...e marks of Renishaw plc in the United Kingdom and other countries apply innovation and names and designations of other Renishaw products and technologies are trade marks of Renishaw plc or its subsidi...