Renishaw NCi-6 Скачать руководство пользователя страница 6

1-2

NCi-6 non-contact tool setting interface: Before you begin

Safety

In all applications involving the use of machine tools or CMMs, eye protection is recommended .

Information to the machine supplier/ installer

It is the machine supplier’s responsibility to ensure that the user is made aware of any hazards involved in 
operation, including those mentioned in Renishaw product literature, and to ensure that adequate guards 
and safety interlocks are provided .

Under certain circumstances, the probe signal may falsely indicate a probe seated condition . Do not rely 
on probe signals to halt the movement of the machine .

Information to the equipment installer

All Renishaw equipment is designed to comply with the relevant UK, EU and FCC regulatory requirements . 
It is the responsibility of the equipment installer to ensure that the following guidelines are adhered to, in 
order for the product to function in accordance with these regulations:

• 

any interface MUST be installed in a position away from any potential sources of electrical noise, i .e . 
power transformers, servo drives etc .;

• 

all 0 V/ground connections should be connected to the machine “star point” (the “star point” is a single 

point return for all equipment ground and screen cables) . This is very important and failure to adhere 
to this can cause a potential difference between grounds;

• 

all screens must be connected as outlined in the user instructions;

• 

cables must not be routed alongside high current sources, i .e . motor power supply cables etc ., or be 
near high-speed data lines;

• 

cable lengths should always be kept to a minimum .

Equipment operation

If this equipment is used in a manner not specified by the manufacturer, the protection provided by the 

equipment may be impaired .

WARNINGS

Use of controls or adjustments or performance of procedures other than those specified within this 

publication may result in hazardous radiation exposure .

Switch off electrical power to the NCi-6 interface before carrying out maintenance on non-contact (NC) tool 
setting and tool breakage detection products .

CAUTION – LASER SAFETY

The NCi-6 interfaces with Renishaw laser-based non-contact tool setting and tool breakage detection products . 
Laser safety guidelines and safety rules are described in the appropriate NC tool setting product guides .

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the 

equipment may be impaired .

Содержание NCi-6

Страница 1: ...renishaw NCi 6 non contact tool setting interface www renishaw com nci 6 Installation guide...

Страница 2: ...Compliance information for this product is available by scanning the QR code or visiting www renishaw com mtpdoc...

Страница 3: ...output over current protection 2 1 NCi 6 interface unit top face 2 2 NCi 6 interface unit bottom face 2 2 NCi 6 top label 2 3 NCi 6 bottom label 2 3 Connectors CN1 and CN2 2 4 Interface LEDs 2 5 Inter...

Страница 4: ...dth setting 3 2 Tool set mode 1 without drip rejection 3 2 Tool set mode 1 with drip rejection 3 3 Tool set mode 2 3 3 Dimensions and mounting arrangements 3 4 Wiring 3 5 Connecting to the NC unit 3 5...

Страница 5: ...urchased by you from a third party supplier is subject to separate terms and conditions supplied with such equipment and or software You should contact your third party supplier for details CNC machin...

Страница 6: ...should be connected to the machine star point the star point is a single point return for all equipment ground and screen cables This is very important and failure to adhere to this can cause a potent...

Страница 7: ...pk 30 Vdc pk Protection provided by enclosure IP20 BS EN 60529 1992 A2 2013 Altitude Maximum 2000 m 6562 ft Operating temperature 5 C to 55 C 41 F to 131 F Storage temperature 25 C to 70 C 13 F to 15...

Страница 8: ...1 4 NCi 6 non contact tool setting interface Before you begin This page is intentionally left blank...

Страница 9: ...DC power supply from the NCi 6 unit before removing the cover Power supply The NCi 6 interface can draw its power from the CNC machine s nominal 12 Vdc to 24 Vdc supply This must be an appropriate sin...

Страница 10: ...ol setting interface NCi 6 basics NCi 6 interface unit top face NCi 6 interface unit bottom face Top face interface label Diagnostic LEDs Connector CN1 10 way Connector CN2 15 way Removable cover Bott...

Страница 11: ...2 3 www renishaw com nci 6 NCi 6 top label NCi 6 bottom label...

Страница 12: ...last This output can also be used with a hardwired NC unit to switch the transmitter unit on off independently of the receiver Alternatively it can act as a skip sharing module to switch between a non...

Страница 13: ...amber to green as the beam voltage increases If the LED is green after exiting set up mode this indicates that set up has been successful If the LED is not green this indicates that set up has not bee...

Страница 14: ...performance maintenance is required Refer to the applicable installation and user s guide for NC4 Renishaw part number H 2000 5230 or NC4 Renishaw part number H 6270 8501 or NC4 Blue Renishaw part nu...

Страница 15: ...tch locations Switch SW1 used during installation and normal operation Cover tab depress to remove cover Removable cover used to access switches SW2 and SW3 These switches only need to be accessed dur...

Страница 16: ...ed at a whole multiple e g 1000 2000 or 3000 or 500 1000 or 1500 and the spindle override must be disabled Switch bank SW2 CAUTIONS With the SSR output switch es set to Off i e normally open N O the r...

Страница 17: ...2 type 1 and SSR2 type 2 CAUTION If using SSR2 as an oscillating or pulsed output for a trigger signal to the control the level output SSR1 must be used to guarantee a reliable probe status check The...

Страница 18: ...2 10 NCi 6 non contact tool setting interface NCi 6 basics This page is intentionally left blank...

Страница 19: ...s and taps Latch mode This mode of operation allows functions such as checking tools for missing inserts and profile checking For further information about the software for these cycles see Probe soft...

Страница 20: ...s in tool set mode 1 without drip rejection active and in tool set mode 2 Switch SW2 4 sets the pulse width to 20 ms or 100 ms M code 3 can be used to invert the switch setting as shown in the table b...

Страница 21: ...ms 1000 r min or 120 ms 500 r min set by SW1 4 Pulse width 20 ms or 100 ms set by SW2 4 Diagrams shown for normally closed invert for normally open Pulse width Laser status Tool set mode 2 Open Close...

Страница 22: ...4 NCi 6 non contact tool setting interface System installation Dimensions and mounting arrangements Standard DIN rail mounting Alternative mounting 34 6 1 36 134 5 28 M4 2 98 3 86 Dimensions in mm in...

Страница 23: ...3 7 Do not connect screen connections if the NC unit housing is connected to the machine ground reference i e R 1 NC unit Digital voltmeter used only during NC unit set up NCi 6 connector CN1 Set up D...

Страница 24: ...n 5 Normally closed 6 Energise 11 Vdc to 30 Vdc 7 SSR1 voltage free 8 SSR1 voltage free 9 SSR2 voltage free 10 SSR2 voltage free 11 M code 1 tool breakage 12 M code 2 latch mode 13 Screen 14 0 Vdc sup...

Страница 25: ...Vdc to 30 Vdc switches the laser on Low 0 Vdc or floating switches the laser off NCi 6 connector CN1 NCi 6 connector CN2 NC unit Rx Tx Power supply White Purple Blue Black Red Screen Grey 4 Analogue...

Страница 26: ...robe status Machine skip input High 11 Vdc to 30 Vdc selects the AUX probe and may also send the start code Low 0 Vdc or floating selects the NC probe NCi 6 connector CN2 Skip supply voltage 1 2 3 Nor...

Страница 27: ...code High 11 Vdc to 30 Vdc switches the air on Low 0 Vdc or floating switches the air off NC unit Rx Tx Solenoid supply voltage Vdc Imax 200 mA NCi 6 connector CN2 Air supply Vmax 30 Vdc 1 2 3 Normal...

Страница 28: ...3 10 NCi 6 non contact tool setting interface System installation This page is intentionally left blank...

Страница 29: ...4 1 www renishaw com nci 6 Maintenance NCi 6 maintenance No routine maintenance is required Remove dust from the external surfaces with a dry cloth...

Страница 30: ...4 2 NCi 6 non contact tool setting interface Maintenance This page is intentionally left blank...

Страница 31: ...NCi 6 interface A 6516 2000 NCi 6 interface and box with DIN rail mounting and two terminal blocks NCi 6 terminal block 10 way P CN25 1053 10 way socket terminal for NCi 6 interface NCi 6 terminal bl...

Страница 32: ...rade marks of their respective owners WHILE CONSIDERABLE EFFORT WAS MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT AT PUBLICATION ALL WARRANTIES CONDITIONS REPRESENTATIONS AND LIABILITY HOWSOEVER ARISIN...

Отзывы: