3-3
www.renishaw.com/nci-6
Tool set mode 1 (with drip rejection)
Open
Closed
Tool setting with drip rejection
Level
Pulsed
Oscillating
Open
Closed
Open
Closed
Beam clear
Beam blocked
Beam clear
Beam clear
Beam blocked
by drips
Blocks
Drip filter
Drip filter
Clears
Blocks Clears
< Drip filter
S
S
Pulse width
20 ms
20 ms
Drip filter = 60 ms (1000 r/min) or 120 ms (500 r/min), set by SW1-4
Pulse width = 20 ms or 100 ms, set by SW2-4
Diagrams shown for normally closed, invert for normally open
Pulse width
Laser
status
Tool set mode 2
Open
Closed
Tool setting (drip rejection not applicable)
Level
Pulsed
Oscillating
Open
Closed
Open
Closed
Beam blocked
Clears
Beam clear
> Pulse width
Blocks
Clears
< Pulse width
Pulse width = 20 ms or 100 ms, set by SW2-4
Diagrams shown for normally closed, invert for normally open
Laser
status
Blocks
Pulse width
Pulse width
20 ms
20 ms
Pulse width
Содержание NCi-6
Страница 1: ...renishaw NCi 6 non contact tool setting interface www renishaw com nci 6 Installation guide...
Страница 8: ...1 4 NCi 6 non contact tool setting interface Before you begin This page is intentionally left blank...
Страница 11: ...2 3 www renishaw com nci 6 NCi 6 top label NCi 6 bottom label...
Страница 18: ...2 10 NCi 6 non contact tool setting interface NCi 6 basics This page is intentionally left blank...
Страница 28: ...3 10 NCi 6 non contact tool setting interface System installation This page is intentionally left blank...
Страница 30: ...4 2 NCi 6 non contact tool setting interface Maintenance This page is intentionally left blank...