26
Original instructions
15.3 BiSS C serial communications
BiSS C specifications
Function
Signal
Wire colour
Pin-out
9-way D
Power
5 V
Brown
4, 5
0 V
White
8, 9
Serial
communications
MA+
Violet
2
MA−
Yellow
3
SLO+
Grey
6
SLO−
Pink
7
Shield
Shield
Cable braid
Case
BiSS C (unidirectional) output signals
31
16
52
9-way D-type
Power supply
5 V ±10% 1.25 W maximum (250 mA @ 5 V)
NOTES:
X
Current consumption figures refer to terminated FORTiS‑S FS
systems. Renishaw encoder systems must be powered from
a 5 Vdc supply complying with the requirements for PELV of
standard IEC 60950‑1
X
Over voltage protection
±10 V.
Ripple
200 mVpp maximum @ frequency up to 500 kHz
FORTiS-S FS grounding and shielding – BiSS C
Customer
electronics
Extension
cable*
Encoder
Connector
Readhead
cable
IM PORTANT:
The shield should be connected to the machine Earth (Field Ground).
IMPORTANT:
If the flying lead variant is used or the connector is modified or replaced, the customer must
ensure that both 0 V cores (White and Green) are connected to 0 V. In such situations, care should also
be taken to ensure that 0 V and Earth remain properly insulated from each other throughout the cable run.