Certification

FORTiS-S FS encoder system

Functional Safety Certificate No. FSC003

SIL2

FUNCTIONAL

SAFETY

PLd

Under the terms of CSA SIRA Functional Safety Certificate SIRA 

CASS00023/01

, for the 

management and self-certification of functional safety activities up to SIL3/PLd.

Renishaw plc declares that the products listed by this installation guide meet the requirements of:

•  IEC 61508-1:2010, IEC 61508-2:2010 and IEC 61508-3:2010

•  IEC 61800-5-2:2016

•  ISO 13849-1:2015 and ISO 13849-2:2012

When used as an element/subsystem in safety-related systems performing safety functions 
requiring up to and including:

•  SIL2 with HFT = 0 (1oo1)

•  Category 3, PLd.

EUD 2021-00819

This declaration of conformity is issued under the sole responsibility of the manufacturer, Renishaw 

plc. The object of the declaration is identified below:

Product name:

FORTiS-S

 and FS FORTiS-N

 enclosed encoder system

Description:

Enclosed linear FS readhead and scale assembly

Part no.:

Valid from:

Description:

FS1-----------S----

-02

FORTiS-S

 FS standard size enclosed linear encoders

FN1-----------S----

-02

FORTiS-N

 FS narrow size enclosed linear encoders

2006/42/EC

Machinery Directive

2014/30/EU

Electromagnetic Compatibility (EMC)

2011/65/EU

On the restriction of the use of certain hazardous substances in electrical 

and electronic equipment – RoHS

EN ISO 12100:2010

Safety of machinery – General principles for design –  
Risk assessment and risk reduction

EN ISO 13849-1:2015

Safety of machinery – Safety-related parts of control systems  
Part 1: General principles for design (ISO 13849-1:2015)

EN ISO 13849-2:2012

Safety of machinery – Safety-related parts of control systems  
Part 2: Validation (ISO 13849-2:2012)

EN 61326-1:2013

Electrical equipment for measurement, control, and laboratory use. 
EMC requirements 
Part 1: General requirements

EN 62471:2008

Photobiological safety of lamps and lamp systems

EN IEC 63000:2018

Technical documentation for the assessment of electrical and electronic 

products with respect to the restriction of hazardous substances

The object of the declaration described above is in conformity with all relevant EU harmonisation 

legislation and fulfils all the relevant provisions with EU directives:

and complies with the following technical standards:

For the full Declaration of Conformity EUD 2021-00819 see:  

www.renishaw.com/productcompliance

Summary of EU Declaration of Conformity

EU based person authorised to compile the technical file: - Renishaw (Ireland) DAC, Swords 

Business Park, Swords, Co. Dublin, K67 FX67, Ireland.

Содержание FORTiS-S FS

Страница 1: ...renishaw www renishaw com fortisdownloads FORTiS S FS enclosed encoder system with multiple readheads Addendum to M 6725 9016 Installation guide M 6725 9188 01 A...

Страница 2: ...2 FORTiS S enclosed encoder system with multiple readheads This page is left intentionally blank...

Страница 3: ...tification 9 5 Summary of EU declaration of conformity 9 6 Summary of UK declaration of conformity 10 7 Overview of the FORTiS S FS encoder system with multiple readheads 10 8 Parts list 11 8 1 Includ...

Страница 4: ...nal Safety data declaration Safety function Certification Summary of EU declaration of conformity Overview of the FORTiS S FS encoder system Parts list Storage and handling Installation drawings Produ...

Страница 5: ...r Siemens DRIVE CLiQ serial interface lS 6 75E 07 lS 9 94E 07 lS 1 32E 06 lS 1 66E 06 Not permitted Not permitted Not permitted lD 1 19E 06 lD 1 73E 06 lD 2 31E 06 lD 2 89E 06 lDD 1 07E 06 lDD 1 56E 0...

Страница 6: ...ance level d Lifetime replacement limits 20 years The FORTiS S FS encoder system provides safe position data that supports the following safety sub functions defined by IEC 61800 5 2 Safe stop 1 SS1 a...

Страница 7: ...validate the Functional Safety certification of the FORTiS S FS encoder system Faults caused by cutting and reconnecting the cable or the use of a non Renishaw cable that is not approved Incorrect ins...

Страница 8: ...y the system manufacturer according to their risk assessment There are no user serviceable parts within the FORTiS S FS encoder system The following maintenance actions are advised Check the extrusion...

Страница 9: ...EU Electromagnetic Compatibility EMC 2011 65 EU On the restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS EN ISO 12100 2010 Safety of machinery General...

Страница 10: ...fer to the FORTiS S FS enclosed encoder system Functional Safety installation guide and safety manual Renishaw part no M 6725 9016 UKD 2021 00819 This declaration of conformity is issued under the sol...

Страница 11: ...urely connecting the encoder cable to the readhead Alignment brackets Two brackets to secure each readhead during transit and set the correct readhead alignment during installation IMPORTANT Retain un...

Страница 12: ...head mounting screws 1 5 mm hex key Air bung removal only if air purge is required 4 mm hex key For locking the mounting aid For use with the M5 extrusion and M5 readhead screw options 5 mm hex key Fo...

Страница 13: ...plications that require multiple readheads traversing a single extrusion the extrusion is fixed with only the readheads moving Please contact your local Renishaw representative if your requirements ar...

Страница 14: ...type A B C Minimum static bend radius Black 137 181 137 15 Green 154 216 154 31 5 Armoured 170 247 170 45 NOTES 1 For required installation information see FORTiS S FS system installation drawings in...

Страница 15: ...1 8 W maximum 75 mA 24 V 24 V as per DRIVE CLiQ specification 24 V power is provided by the DRIVE CLiQ network NOTE Over voltage protection 36 V to 36 V Ripple 200 mVpp maximum frequency up to 500 kHz...

Страница 16: ...t or company names are trade marks of their respective owners Renishaw plc Registered in England and Wales Company no 1106260 Registered office New Mills Wotton under Edge Glos GL12 8JR UK 44 0 1453 5...

Отзывы: