INSTALLATION AND OPERATION MANUAL 

Model BR70/BR130 

 Units should be installed by properly licensed contractor(s) according to local 

code requirements. 

 

 

 

 

 

 

 

 

BR Unit (door closed) 

 

 

 

 

 

 

BR Unit (door open) 

 

 

 

 

 

 

 

 

 

 

 

TW Kit 

 

 

 

  

R

ISK OF 

F

IRE

,

 

E

LECTRIC 

S

HOCK

,

 OR 

I

NJURY

.

  

O

BSERVE ALL 

CODES AND THE FOLLOWING

1.

 

 Use the unit only in the manner intended by the 
manufacturer.  If you have questions, contact the 
manufacturer. 

2.

 

Unplug the unit before servicing or cleaning.  

CAUTION:

 more than one disconnect switch may be 

required to de-energize the equipment for servicing. 

3.

 

Do not use in cooking area. 

4.

 

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment that might be installed in the area 
affected by this equipment.  If this unit is exhausting air 
from a space in which chimney-vented fuel burning 
equipment is located, take steps to assure that combustion 
air supply is not affected.  Follow the heating equipment 
manufacturer's guidelines and safety standards such as 
those published by the National Fire Protection 
Association (NFPA), the American Society for Heating, 
Refrigeration and Air Conditioning Engineers 
(ASHRAE), and local code authorities. 

5.

 

Do not connect this unit to fume hoods or collection 
systems for toxics. 

6.

 

Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable 
codes and standards, including fire-rated construction 
codes and standards. 

7.

 

When cutting or drilling into wall or ceiling, do not 
damage electrical wiring and other hidden utilities. 

8.

 

This unit must be properly vented to the outside. 

9.

 

This unit must be connected to a properly grounded 
power outlet. 

 
 

 

1.

 

This unit is intended for general ventilating use only.  Do 
not use to exhaust hazardous or explosive materials and 
vapors. 

2.

 

To avoid motor bearing damage and noisy and/or 
unbalanced impellers, keep drywall spray, construction 
dust, etc., off power unit. 

3.

 

This installation manual shows the suggested installation 
method.  Any structural alterations necessary for 
installation must comply with all applicable building, 
health, and safety code requirements. 

WARNING

 

BR130 (Door Closed) 

BR130 (Door Open) 

CAUTION 

Содержание Breeze BR70

Страница 1: ...imney vented fuel burning equipment is located take steps to assure that combustion air supply is not affected Follow the heating equipment manufacturer s guidelines and safety standards such as those...

Страница 2: ...ing extremely cold weather The fresh air intake vent from the outside is placed a minimum of ten feet from any other exhaust vent The power cord reaches an electrical outlet The front cover can be ope...

Страница 3: ...void cross contamination Keep the length of the two flexible ducts roughly equal and as short and straight as possible Normally six inch insulated flexible duct is used Band or tape inner duct liner t...

Страница 4: ...e flex duct is not required for the room air connection RA This will cut noise transmitted from the unit Stretch the flex duct tightly in order to maintain good airflow For houses with forced air heat...

Страница 5: ...e installing contractor As an alternative you may wish to produce your own filters following these instructions Filters may be cut from a sheet or roll of 1 firm spun polyester filter hog hair media o...

Страница 6: ...ight 45 lbs 55 lbs Power 0 08 HP 1 0 amps 85 watts at 70 CFM 0 1 HP 1 3 amps 123 watts at 130 CFM Access Cover Front panel opens to provide access to filters blowers and heat exchanger Snap latches an...

Страница 7: ...newaire com Parts List BR70 BR130 Description A Door Assembly L Interlock Switch B Core assembly M E Box C Filter set of 2 N Hardware Kit D Label O Literature Packet E Blower Wheel Divider Side P Hing...

Страница 8: ...see chart below based on either the size of the house or the number of occupants bedrooms Breeze will automatically provide this rate every hour Smokers will generally need about double the usual ven...