background image

 

To our customers, 

 

Old Company Name in Catalogs and Other Documents 

 

On April 1

st

, 2010, NEC Electronics Corporation merged with Renesas Technology 

Corporation, and Renesas Electronics Corporation took over all the business of both 
companies. Therefore, although the old company name remains in this document, it is a valid 
Renesas Electronics document. We appreciate your understanding. 
 

Renesas Electronics website: 

http://www.renesas.com

 

 
 
 
 

April 1

st

, 2010 

Renesas Electronics Corporation 

 

 
 
 
 

Issued by: 

Renesas Electronics Corporation

 (

http://www.renesas.com

Send any inquiries to 

http://www.renesas.com/inquiry

 

Содержание SH7085

Страница 1: ...ook over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electronics website http www renesas com April 1st 2010 Renesas Electronics Corporation Issued by Renesas Electronics Corporation http www renesas com Send any inquiries to http www renesas com inquiry ...

Страница 2: ...ct for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas Electronics product is Standard unless otherwise expressly specified in a Renesas Electronics data sheets or data books etc Standard Computers office equipment communications equipment test and meas...

Страница 3: ...SH7085 Group PLQP0144KA A User System Interface Board User s Manual User s Manual Rev 4 00 2007 02 Renesas Microcomputer Development Environment System SuperH Family SH7080 Series R0E570850CFK00 ...

Страница 4: ......

Страница 5: ... such as safety systems or equipment or systems for transportation and traffic healthcare combustion control aerospace and aeronautics nuclear power or undersea communication transmission If you are considering the use of our products for such purposes please contact a Renesas sales office beforehand Renesas shall have no liability for damages arising out of the uses set forth above 8 Notwithstand...

Страница 6: ......

Страница 7: ...e board is used to connect the evaluation chip unit to the user system This user system interface board must only be used for the above purpose Limited Applications This emulator product is not authorized for use in transportation vehicular medical where human life is potentially at stake aerospace nuclear or undersea repeater applications Buyers of this emulator product must notify Renesas Techno...

Страница 8: ...ion or some experiment else 2 In no event shall Renesas Solutions Corporation be liable for any consequence arising from the use of this emulator 3 Renesas Solutions Corporation strives to renovate or provide a workaround for product malfunction at some charge or without charge However this does not necessarily mean that Renesas Solutions Corporation guarantees the renovation or the provision unde...

Страница 9: ...chases the emulator product from you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HEREIN INCLUDING WITHOUT LIMITATION THEREOF WARRANTIES AS TO MARKETABILITY MERCHANTABILITY FITNESS FOR ANY PARTICULAR PURPOSE OR USE OR AGAINST INFRINGEMENT OF ANY PATENT I...

Страница 10: ... system All Rights Reserved 1 Circuitry and other examples described herein are meant merely to indicate the characteristics and performance of Renesas semiconductor products Renesas assumes no responsibility for any intellectual property claims or other problems that may result from applications based on the examples described herein 2 No license is granted by implication or otherwise under any p...

Страница 11: ... alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAU...

Страница 12: ...VI means WARNING or CAUTION Example CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION Example DISASSEMBLY PROHIBITED means A FORCIBLE ACTION Example UNPLUG THE POWER CABLE FROM THE RECEPTACLE ...

Страница 13: ...onnected signal ground with frame ground If your developing product is transformless not having isolation transformer of AC power this may cause electric shock Also this may give an unrepairable damage to this product and your developing one While developing connect AC power of the product to commercial power through isolation transformer in order to avoid these dangers If other equipment is conne...

Страница 14: ...uipment Warnings to Be Taken for This Product Do not disassemble or modify this product Personal injury due to electric shock may occur if this product is disassembled and modified Make sure nothing falls into the cooling fan on the top panel especially liquids metal objects or anything combustible Warning for Installation Do not set this product in water or areas of high humidity Make sure that t...

Страница 15: ...apter is always active while connecting the AC power cable Cautions to Be Taken for This Product Use caution when handling this product Be careful not to apply a mechanical shock Do not pull the main unit by the probe of the emulation probe or the flexible cable which are connected to this product Excessive flexing or force of the flexible cable for connecting this product to the emulation probe m...

Страница 16: ...r or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E200F emulator and user system before connecting or disconnecting any CABLES or PARTS 3 Always before connecting any CABLES make sure that pin 1 on both sides are correctly aligned 4 If cables are connected incorrectly the power pins will be short circuited in the following way...

Страница 17: ...reface The R0E570850CFK00 is a user system interface board that connects a user system for the SH7085 PLQP0144KA A former code FP 144LV package to the SH7080 E200F emulator R0E0200F1EMU00 or R0E570800VKK00 ...

Страница 18: ...ii ...

Страница 19: ...able Head 10 4 1 3 Fastening Cable Head 10 4 2 Connecting User System Interface Board to EV Chip Board 12 4 3 Recommended Dimensions for User System Mount Pad Footprint 14 4 4 Dimensions for External Bus Trace Unit Emulation Memory Unit EV Chip Unit and User System Interface Board 15 4 5 Resulting Dimensions after Connecting User System Interface Board 17 Section 5 Installing the MCU to the User S...

Страница 20: ...iv ...

Страница 21: ... board for the PLQP0144KA A former code FP 144LV package Please make sure you have all of these components when unpacking Board Screws M2 0 x 10 mm Spacer IC socket User system Screws M2 0 x 6 mm Socket cover EV chip unit Figure 1 User System Interface Board for the SH7085 PLQP0144KA A Former Code FP 144LV Package ...

Страница 22: ...ts No Component Quantity Remarks 1 Board 1 With four spacers 2 6MP x 11 mm 2 IC socket 1 For the PLQP0144KA A former code FP 144LV package to be mounted on the user system 3 Socket cover 1 For the PLQP0144KA A former code FP 144LV package for installing MCU 4 Screws M2 0 x 10 mm 4 For fastening board 5 Screws M2 0 x 6 mm 4 For installing a PLQP0144KA A former code FP 144LV packaged MCU 6 Guide pin...

Страница 23: ...ental Conditions Item Specifications Temperature Operating 10 to 35 C Storage 10 to 35 C Humidity Operating 35 to 80 RH no condensation Storage 35 to 80 RH no condensation Vibration Operating 2 45 m s 2 max Storage 4 9 m s 2 max Transportation 14 7 m s 2 max Ambient gases There must be no corrosive gases present ...

Страница 24: ...4 ...

Страница 25: ...he emulation memory function is used the output of the chip select signals to the user system is controlled Be sure to mask the chip select signals CS0 to CS7 that correspond to the address area to which the emulation memory has been allocated Figure 2 Switch for Masking Signals WARNING Always switch OFF the user system and the emulator product before the switches are set Failure to do so will res...

Страница 26: ...BREQ TEND0 Mask canceled Mask enabled 6 29 PA20 _CS4 _RASU Mask canceled Mask enabled Table 4 Setting a Switch SW2 Switch Setting SW2 No PLQP0144KA A Former Code FP 144LV Socket Pin No Signal Name On Off 1 38 PB7 A19 _BREQ IRQ5 TXD0 Mask canceled Mask enabled 2 39 PB8 A20 _WAIT IRQ6 SCK0 Mask canceled Mask enabled 3 57 PD28 D28 _CS2 TIOC3DS Mask canceled Mask enabled 4 56 PD29 D29 _CS3 TIOC3BS Mas...

Страница 27: ...P 144LV Socket Pin No Signal Name On Off 1 101 PA17 _WAIT DACK2 Mask canceled Mask enabled 2 4 PA21 _CS5 _CE1A _CASU TIC5U Mask canceled Mask enabled 3 115 PE5 _CS6 _CE1B TIOC1B TXD3 Mask canceled Mask enabled 4 116 PE6 _CS7 TIOC2A SCK3 Mask canceled Mask enabled 5 Unused 6 Unused ...

Страница 28: ...PB7 PB8 PD28 PD29 PA18 PA17 PA1 PA11 PE6 PA7 PE5 PA0 PA10 PA20 PA6 PA21 SW1 SW2 SW3 User system Emulator PB7_C PB8_C PD28_C PD29_C PA18_C PA17_C PA1_C PA11_C PE6_C PA7_C PE5_C PA0_C PA10_C PA20_C PA6_C PA21_C Figure 3 Circuit for Masking Signals Note The UVcc is the Vcc in the user system ...

Страница 29: ...ligned Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 4 1 1 Installing IC Socket Solder the IC socket for a PLQP0144KA A FP 144LV package to the user system CAUTION Be sure to completely solder the leads s...

Страница 30: ...figure 4 4 1 3 Fastening Cable Head CAUTION 1 Use a Phillip type screwdriver whose head matches the screw head 2 The tightening torque must be 0 054 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or...

Страница 31: ...ime alternating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components Board Screws M2 0 x 10 mm User system IC socket NQPACK144SD ND manufactured by Tokyo Eletech Corporation Pin 1 Figure 4 Connecting User System Interface Board to User S...

Страница 32: ...user system and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system interface board dedicated to the emulator must be used 1 Make sure the user system and emulator are turned off 2 Align the connectors on the board with those on the EV chip board according t...

Страница 33: ...acer User system EV chip unit Connector No User I F Connector 1 CN4 EV Chip Unit Connector No Board Connector No UCN1 UCN2 User I F Connector 2 CN5 Figure 5 Connecting User System Interface Board to EV Chip Board ...

Страница 34: ...age NQPACK144SD ND manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad 0 50 0 25 7 00 23 00 19 00 0 5 x 35 17 5 7 0 2 00 0 5 x 35 17 5 SL type 0 50 Unit mm Dimension and tolerance Tolerance 0 05 0 10 0 15 0 20 0 30 Dimension Up to 1 2 1 3 to 2 0 2 1 to 5 0 5 1 to 10 0 10 1 or above Figure 6 Recommended Dime...

Страница 35: ...ernal Bus Trace Unit Emulation Memory Unit EV Chip Unit and User System Interface Board The dimensions for the external bus trace unit emulation memory unit EV chip unit and the user system interface board are shown in figure 7 ...

Страница 36: ...20 0 30 0 60 0 5 0 125 0 90 0 Unit mm Tolerance 0 5 mm External bus trace unit Board Spacer EV chip unit Pin 1 Emulation memory unit Figure 7 Dimensions for External Bus Trace Unit Emulation Memory Unit EV Chip Unit and User System Interface Board ...

Страница 37: ...5 55 0 12 5 68 4 30 0 37 5 27 5 29 2 24 5 39 19 39 19 24 5 IC socket NQPACK144SD ND manufactured by Tokyo Eletech Corporation User system Spacer φ6 0 Unit mm EV chip unit Tolerance 1 0 mm Pin 1 Top view External bus trace unit Emulation memory unit Figure 8 Resulting Dimensions after Connecting User System Interface Board when Connecting External Bus Trace Unit Emulation Memory Unit and EV Chip Un...

Страница 38: ...144SD ND manufactured by Tokyo Eletech Corporation User system Spacer φ6 0 Unit mm Tolerance 1 0 mm Pin 1 Top view External bus trace unit EV chip unit Figure 9 Resulting Dimensions after Connecting User System Interface Board when Connecting External Bus Trace Unit and EV Chip Unit ...

Страница 39: ...acer φ6 0 IC socket NQPACK144SD ND manufactured by Tokyo Eletech Corporation User system Unit mm Tolerance 1 0 mm 24 5 39 19 39 19 24 5 Pin 1 Top view Figure 10 Resulting Dimensions after Connecting User System Interface Board when Connecting EV Chip Unit ...

Страница 40: ...20 ...

Страница 41: ...ch the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin 1 before inserting the MCU into the IC socket on the user system as shown in figure 11 After inserting the MCU fas...

Страница 42: ...22 MCU SH7085 Screws M2 0 x 6 mm Socket cover Pin 1 User system IC socket NQPACK144SD ND manufactured by Tokyo Eletech Corporation Figure 11 Installing MCU to User System ...

Страница 43: ...ck Select the clock in the emulator by the CLOCK command emulator command To use the external clock on the user system Supply the external clock from the user system to the emulator by inputting the EXTAL pin pin 96 on the user system interface board or connecting the crystal oscillator to the XTAL pin 94 and EXTAL pins For details refer to section 4 Clock Pulse Generator in the SH7080 Group Hardw...

Страница 44: ...24 ...

Страница 45: ...dimensions of the recommended mount pad for the IC socket for this user system interface board are different from those of the MCU 4 This user system interface board is specifically designed for the SH7080 E200F EV chip unit R0E570800VKK00 Do not use this board with any other emulator 5 When power is not supplied to the Vcc pin on the user system interface board the emulator displays VCC DOWN The ...

Страница 46: ...26 ...

Страница 47: ...ate Rev 1 00 December 14 2004 Rev 4 00 February 26 2007 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Customer Support Department Global Strategic Communication Div Renesas Solutions Corp 2007 Renesas Technology Corp All rights reserved Printed in Japan ...

Страница 48: ...8 Renesas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City 1 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2730 6071 Renesas Technology Taiwan Co Ltd 10th Floor No 99 Fushing North Road Taipei Taiwan Tel 886 2 2715 2888 Fax 886 2 2713 2999 Renesas Technology Singapore Pte Ltd 1 Harbour Front Avenue 06 10 Keppel Bay Tower Singapore 098632 Tel 65...

Страница 49: ......

Страница 50: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan SH7085 Group PLQP0144KA A User System Interface Board REJ10J1205 0400 User s Manual ...

Отзывы: