R01AN5644EJ0100 Rev.1.00
Page 39 of 62
Jan 22, 2021
Reference Guide for a 2-Axis Robot Arm with 2-Phase Stepping
Motors Incorporating Resolvers
RX24T, RX72M,
RAA3064002GFP/RAA3064003GFP
Table 2-8 Messages Sent to the GUI
Corresponding
No.
Message
A-1
[Error] Received response in Broadcast command
A-2
[Error] Time out
A-3
[Error] CRC error
A-4, B-4
[Error] Exception response: FNC = 0x (n1), CODE = (n2)
n1: Function code (8-bit value with MSB = 1)
n2: Exception code
<Examples of exception codes>
•
A CP control position reference value was sent in a mode other than CP control
mode. (Exception code = 1)
•
A PTP control position reference value was sent in a mode other than PTP control
mode. (Exception code = 1)
•
A non-existent address was specified. (Exception code = 2)
•
An invalid data range was set. (Exception code = 3)
•
The sync signal query immediately after a CP position reference has not been
received by the RX24T. (Exception code = 4)
A-5
[Error] Mismatch FNC-No
A-6
[Error] Mismatch Slave-address
B-1
[Error] RDY = 0
B-2, B-3
[Error] ERR0
−
ERR3: 0x (n)
n: Four bits [15:12] of a 1-bit tangent-point data address (error information)
B-5
B-6
B-7
B-8
B-9
B-10
[Error] Arm moving
B-11
[Error] Frequency of CP