R01UH0092EJ0110 Rev.1.10
Page 442 of 807
Jul 31, 2012
M16C/64C Group
22. Remote Control Signal Receiver
22.3.5
Input Capture Mode (Simultaneous Count Operation of PMC0 and PMC1)
PMC0 and PMC1 inputs can be measured simultaneously in input capture mode.
Table 22.19
Input Capture Mode Specifications (Simultaneous Count Operation)
Item
Content
PMC0 Circuit
PMC1 Circuit
Count
sources
Clock sources
Count source of PMC1
One of the following:
•
fC
•
f1
•
Timer B1 underflow
•
Timer B2 underflow
Division
No division
No division, divided-by-8, divided-
by-32, or divided-by-64
Count operation
Increment
Measured items
One of the following:
Pulse period (between rising edge and rising edge)
Pulse period (between falling edge and falling edge)
Pulse width (both high level and low level)
Interrupt request generation
timing
•
Timer measurement
•
Counter overflow
Selectable functions
•
Input signal inversion
•
Digital filter
Содержание M16C Series
Страница 846: ...M16C 64C Group R01UH0092EJ0110...