R01UH0092EJ0110 Rev.1.10
Page 411 of 807
Jul 31, 2012
M16C/64C Group
22. Remote Control Signal Receiver
22.2.3
PMCi Function Select Register 2 (PMCiCON2) (i = 0, 1)
b7 b6 b5 b4
b1
b2
b3
Symbol
PMC0CON2
Address
01F2h
Reset Value
0000 00X0b
b0
Function
Bit Symbol
Bit Name
RW
PMC0 Function Select Register 2
0
RW
ENFLG
PMC0 status flag
0: Stops
1: Operating
—
(b1)
Reserved bit
Read as undefined value
—
(b2)
Reserved bit
Set to 0
INFLG
Input signal flag
0: No overflow
1: Overflows
CEFLG
Counter overflow flag
0: Disabled
1: Enabled
CEINT
0: PMC0 internal input signal level is low
1: PMC0 internal input signal level is high
Counter overflow
interrupt enable bit
PSEL0
Input pin select bit
PSEL1
b7 b6
0 0 : Same as PMC1
(Set bits PSEL1 to PSEL0 in the
PMC1CON2 register to select)
0 1 : PMC0 pin
1 0 : Do not set
1 1 : Do not set
RW
RW
RO
RO
RO
RO
b7 b6 b5 b4
b1
b2
b3
Symbol
PMC1CON2
Address
01FAh
Reset Value
0000 00X0b
b0
Function
Bit Symbol
Bit Name
RW
PMC1 Function Select Register 2
0
RW
ENFLG
PMC1 status flag
0: Stops
1: Operating
INFLG
Input signal flag
0: Disabled
1: Enabled
CEINT
0: PMC1 internal input signal level is low
1: PMC1 internal input signal level is high
Counter overflow interrupt
enable bit
PSEL0
Input pin select bit
PSEL1
b7 b6
0 0 : In an idle state
0 1 : PMC0 pin
1 0 : PMC1 pin
1 1 : Do not set
RW
RW
RO
RO
RO
RO
—
(b1)
Reserved bit
Read as undefined value
—
(b2)
Reserved bit
Set to 0
0: No overflow
1: Overflows
CEFLG
Counter overflow flag