Quick Start 

Renesas Starter Kit for M16C/29 

 
 

 

 

 

1. Installation 

 
Do not connect the E8a module until the software support has been installed. 
 
1

 

Insert the CD into your computer’s CD-ROM drive. The CD should automatically run the installation program. If the installer does not start, browse to 
the RSK directory from the CD root folder and double click on ‘setup.exe’. 

2

 

The installer will ask you which language is to be used, please choose the appropriate one. 

3

 

On the first screen of the installer proper, click <Next>. 

4

 

The License Agreement will be shown, click <Yes>. 

5

 

The next screen asks you to pick the world region – please select and click <Next>. 

6

 

Select the RSK you wish to install and click <Next>. 

7

 

The destination folders are specified on the next screens.  It is recommended to accept the default settings. Click <Next> to continue. 

8

 

Click <Next> on all screens until the Installation process commences. 

9

 

After the installation the machine’s site code will be shown, this is not important at this stage, click <Next> then <Finish>. 

10

 

The Auto-update dialog box will be launched. Configure the Auto-update settings dialog to allow the installation to be checked for available updates. 

D006174_11_S01_V04 

Содержание M16C/29

Страница 1: ...roper click Next 4 The License Agreement will be shown click Yes 5 The next screen asks you to pick the world region please select and click Next 6 Select the RSK you wish to install and click Next 7 The destination folders are specified on the next screens It is recommended to accept the default settings Click Next to continue 8 Click Next on all screens until the Installation process commences 9...

Страница 2: ...orkshop Manual Navigator 17 Launch HEW from the Start Menu Start Menu All Programs Renesas Renesas High performance Embedded Workshop 18 In the Welcome dialog box Verify Create New Workspace is selected Click OK 19 In the New Project Workspace dialog box Set the CPU Family to M16C and verify the Tool chain is set to Renesas M16C Standard Select E8A_RSKM16C29 from the left hand pane 20 Enter a name...

Страница 3: ...p of the memory map 32 Enter 3300 for the Work RAM location It is recommended that the Work RAM is towards the top of the memory map 33 Ensure that the checkbox Debugging of program that uses WDT is not checked 34 Click Next 35 The MCU Setting view will be shown Leave the default options as shown 36 Click Finish Note The first time the E8a is connected you may be asked to choose a driver select Re...

Страница 4: ...t time limited You have 60 days to evaluate the full product before the compiler will limit the code linker to 64k bytes Full licensed M16C compiler versions are available from your Renesas supplier 7 Support Online technical support and information is available at www renesas com renesas_starter_kits Technical Contact Details America techsupport rta renesas com Europe tools support eu renesas com...

Отзывы: