![Renesas M-Station Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/renesas/m-station/m-station_user-manual_1440156026.webp)
M-Station Baseboard
Table 1
Settings
2.
JP3
Jumper
Jumper Setting
Description
Default Setting
No jumper
VDD_SEL = 2.0V
1 to 2
VDD_SEL = 2.5V
3 to 4
VDD_SEL = 3.0V
5 to 6
VDD_SEL = 3.3V
7 to 8
VDD_SEL = 3.5V
9 to 10
VDD_SEL = 4.0V
11 to 12
VDD_SEL = 4.5V
JP3
13 to 14
VDD_SEL = 5.0V
13 to 14
R10
User-selected
V
DD
(refer to Section 3.4)
5.3
JP4: Multiple V
DD
Select
Figure 14.
JP4 Settings
Table 1
Settings
3.
JP4
Jumper Setting
Description
Default
1 to 2
VPX = 5.0V
3 to 4
VPX = 6.8V
5 to 6
VPX = 7.8V
7 to 8
VPX = 8.8V
JP4
9 to 10
VPX = 10V
9 to 10
R11
User-selected VPX (refer to section 3.5)
18