M-Station Baseboard
4. APPLICATION
DEVELOPMENT AID HARDWARE RESOURCES
This section describes various M-Station resources, including connection options, jumper settings, and
part numbers with manufacturer and purchase sources.
4.1 RS-232
Transceiver
The RS-232 transceiver is mounted on the M-Station as a standard feature. The optional DB9 (J6)
connector has a footprint only on the M-Station. SB26 and SB27 are solder-blobs (SBs) with closely
spaced pads. The default configuration connects SBs with 0
Ω
resistors that easily can be removed, if
necessary. When you need to reconnect, use a sufficient amount of solder to short two pads (hence, it
is a called “solder-blob").
Figure 10.
RS-232 Transceiver
Table 6.
Jumper Settings
Jumper
Jumper Setting
Description
Default Setting
JP6
User option
Loopback jumper for RxD and TxD
Open
JP7
User option
Loopback jumper for RTS and CTS
1 to 2