background image

 

To our customers, 

 

Old Company Name in Catalogs and Other Documents 

 

On April 1

st

, 2010, NEC Electronics Corporation merged with Renesas Technology 

Corporation, and Renesas Electronics Corporation took over all the business of both 
companies. Therefore, although the old company name remains in this document, it is a valid 
Renesas Electronics document. We appreciate your understanding. 
 

Renesas Electronics website: 

http://www.renesas.com

 

 
 
 
 

April 1

st

, 2010 

Renesas Electronics Corporation 

 

 
 
 
 

Issued by: 

Renesas Electronics Corporation

 (

http://www.renesas.com

Send any inquiries to 

http://www.renesas.com/inquiry

 

Содержание H8/3694

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...8 36014 Group TNP 48 User System Interface Cable for E6000 Emulator User s Manual User s Manual Rev 1 0 2003 12 HS36014ECN61H Renesas Microcomputer Development Environment System H8 Family H8 300H Tin...

Страница 4: ...described here may contain technical inaccuracies or typographical errors Renesas Technology Corp assumes no responsibility for any damage liability or other loss rising from these inaccuracies or err...

Страница 5: ...system interface cable must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy of...

Страница 6: ...om you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HE...

Страница 7: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas prior written consent Other Important Things to Keep in Mind 1 Circuitry and...

Страница 8: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Страница 9: ...in PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator...

Страница 10: ...rocomputer H8 3694 group and H8 36014 group The HS36014ECN61H is a user system interface cable that connects an H8 3694 group H8 36014 group E6000 emulator HS3664EPI61H hereinafter referred to as the...

Страница 11: ...C Socket 6 2 2 2 Soldering IC Socket 7 2 2 3 Inserting Cable Head 7 2 2 4 Fastening Cable Head 8 2 2 5 Fastening Cable Body 10 2 3 Recommended Dimensions for User System Mount Pad 11 2 4 Dimensions fo...

Страница 12: ...em Figure 1 shows the configuration of the HS36014ECN61H user system interface cable for the TNP 48 package User system IC socket Cable head To emulator station Cable body Screws M2 x 10 mm for fasten...

Страница 13: ...3 IC socket 1 For the TNP 48 package 4 Socket cover 1 For installing a TNP 48 packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For installing a TNP 48 packaged MCU 7 C...

Страница 14: ...SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator...

Страница 15: ...4 Figure 2 Connecting User System Interface Cable to Emulator Station...

Страница 16: ...BLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will result in a FIRE HAZARD and will damage the user system an...

Страница 17: ...ring CAUTION After confirming the location of pin 1 on the IC socket apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket and fasten it to the user system Use t...

Страница 18: ...over the leads and forms solder fillets Use slightly more solder than the MCU 2 2 3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting Align pin 1 on the IC socket for a TNP 48...

Страница 19: ...when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error...

Страница 20: ...Each screw should be tightened a little at a time alternating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC soc...

Страница 21: ...10 2 2 5 Fastening Cable Body Connect the cable body to the cable head Figure 5 Fastening Cable Body...

Страница 22: ...tem with an IC socket for a TNP 48 package NLPACK048SD manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad 5...

Страница 23: ...12 2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Figure 7 Dimensions for User System Interface Cable Head...

Страница 24: ...Connecting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 8 Figure 8 Resulting Dimensions after Conne...

Страница 25: ...screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction wi...

Страница 26: ...15 Figure 9 Installing MCU to User System...

Страница 27: ...e external clock from the OSC1 terminal on the cable head or connecting a crystal oscillator to the OSC1 and OSC2 terminals When a crystal oscillator is inserted into the OSC1 and OSC2 terminals for t...

Страница 28: ...17 Figure 10 shows the system clock oscillator on the user system interface cable and the subclock input specifications Figure 10 System Clock Oscillator...

Страница 29: ...pecifically designed for the HS3664EPI61H emulator Do not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on t...

Страница 30: ...per pin SW1 is a switch provided for selection of the H8 3694 group or the H8 36014 group Shift the switch to 3694 or 36014 when the H8 3694 group or the H8 36014 group is in use respectively At defau...

Страница 31: ...r s Manual Publication Date Rev 1 00 December 19 2003 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department Renesas Kodaira Semicon...

Страница 32: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan H8 3694 H8 36014 Group TNP 48 User System Interface Cable for E6000 Emulator REJ10B0094 0100H User s Manual...