- 109 -
set_flg Set
eventflag
iset_flg
Set eventflag (handler only)
[
[
[
[
C
C
L
L
a
a
n
n
g
g
u
u
a
a
g
g
e
e
A
A
P
P
I
I
]
]
]
]
ER ercd = set_flg( ID flgid, FLGPTN setptn );
ER ercd = iset_flg( ID flgid, FLGPTN setptn );
z
z
P
P
a
a
r
r
a
a
m
m
e
e
t
t
e
e
r
r
s
s
ID
flgid
ID number of the eventflag to be set
FLGPTN
setptn
Bit pattern to be set
z
z
R
R
e
e
t
t
u
u
r
r
n
n
P
P
a
a
r
r
a
a
m
m
e
e
t
t
e
e
r
r
s
s
ER ercd Terminated
normally (E_OK)
[
[
[
[
A
A
s
s
s
s
e
e
m
m
b
b
l
l
y
y
l
l
a
a
n
n
g
g
u
u
a
a
g
g
e
e
A
A
P
P
I
I
]
]
]
]
.include mr100.inc
set_flg FLGID,SETPTN
iset_flg FLGID,SETPTN
z
z
P
P
a
a
r
r
a
a
m
m
e
e
t
t
e
e
r
r
s
s
FLGID
ID number of the eventflag to be set
SETPTN
Bit pattern to be set
z
z
R
R
e
e
g
g
i
i
s
s
t
t
e
e
r
r
c
c
o
o
n
n
t
t
e
e
n
n
t
t
s
s
a
a
f
f
t
t
e
e
r
r
s
s
e
e
r
r
v
v
i
i
c
c
e
e
c
c
a
a
l
l
l
l
i
i
s
s
i
i
s
s
s
s
u
u
e
e
d
d
Register name
Content after service call is issued
R0 Error
code
R2
Eventflag ID number
A1
Bit pattern to be set
[
[
[
[
E
E
r
r
r
r
o
o
r
r
c
c
o
o
d
d
e
e
]
]
]
]
None
[
[
[
[
F
F
u
u
n
n
c
c
t
t
i
i
o
o
n
n
a
a
l
l
d
d
e
e
s
s
c
c
r
r
i
i
p
p
t
t
i
i
o
o
n
n
]
]
]
]
Of the 32-bit eventflag indicated by flgid, this service call sets the bits indicated by setptn. In other words, the value of the
eventflag indicated by flgid is OR’d with setptn. If the alteration of the eventflag value results in task-awaking conditions
for a task that has been kept waiting for the eventflag by the wai_flg or twai_flg service call becoming satisfied, the task is
released from WAITING state and placed into READY or RUNNING state.
Task-awaking conditions are evaluated sequentially beginning with the top of the waiting queue. If TA_WMUL is specified
as an eventflag attribute, multiple tasks kept waiting for the eventflag can be released from WAITING state at the same
time by one set_flg or iset_flg service call issued. Furthermore, if TA_CLR is specified for the attribute of the target event-
flag, all bit patterns of the eventflag are cleared, with which processing of the service call is terminated.
If all bits specified in setptn are 0, no operation will be performed for the target eventflag, in which case no errors are as-
sumed, however.
If this service call is to be issued from task context, use set_flg; if issued from non-task context, use iset_flg.
Содержание Emulator System M3T-MR100
Страница 3: ...M3T MR100 4 V 1 00 User s Manual User s Manual Rev 1 00 2007 09 Real time OS for R32C 100 Series...
Страница 6: ......
Страница 14: ......
Страница 16: ...xii...
Страница 18: ......
Страница 78: ......
Страница 242: ......
Страница 269: ...253 235 entry_address alm2 236 name ID_alm2 237 exinf 0x12345678 238 239 240 241 242 End of Configuration 243...
Страница 279: ...263...
Страница 290: ......
Страница 294: ......
Страница 304: ...288...
Страница 306: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan M3T MR100 4 V 1 00 REJ10J1523 0100 User s Manual...