Operation
Overview of display values and settings
List of available time programs
With maximum controller configuration
Select timer program using
Ç
Ä
select timer program for display or adjustment
CIRCL TIME
Switching program for circulation pump
HOTW-PROG
Enabling program for hot water charging pump
HEAT-PROG 1
D
1
1. heating program for first controller heating circuit
HEAT-PROG 2
D
1
2nd heating program for first controller heating
circuit
HEAT-PROG 1
D
2
1. heating program for second controller heating
circuit
HEAT-PROG 2
D
2
2nd heating program for second controller heating
circuit
RETURN
Exit level using
Ä
Timer Program Area
All the time programs can be set in this
area.
~
Hinged cover OPEN
Î
search for
level to the right with
Ç
, open with
Ä
Selecting a timer program
Open hinged cover => "Display =>
System",
Ç
ot the right until clock
=> "USER => INSTALLATION",
Ç
to the right until clock
=> "TIME PROGRAM
=> CIRCL TIME"
Ç
Select timer program
=> e.g. "HEAT-PROG 2
D
1"
= Heating program 2 for controller
heating circuit 1
Ä
Confirm/open timer program
=> "MONDAY"
When connecting a digital room
controller with
heating program input
,
the corresponding heating program in
this controller is automatically faded
out.
Ç
Select another weekday/block for
entry or exit heating program 2 with
"RETURN" and set another program.
!
The heating times are not saved
until all the times for a weekday/
block have been entered.
„- - - -“ for a switch-on/switch-off time
=> The relevant heating timer is
deactivated.
Timer/heating program adjustment
Ç
Select weekday (Mo-Su) or block
(MO-FR => Monday-Friday, SA-SU =>
Saturday-Sunday, MO-SU =>
Monday-Sunday)
Ä
Open weekday/block (see right)
=
>
"I ON 20°C" First switch-on time -
set value I = 20°C
Ç
Set first switch-on time => for
example 6:00 hrs
Ä
Confirm first switch-on time
=
>
„I OFF 20°C" First switch-off time -
set value I = 20°C
Ç
Set first switch-off time => for
example 8:00 hrs
Ä
Confirm first switch-off time
=> „II ON 20°C" Second switch-on time
- set value II = 20°C
Ç
Ä
Switch-on and switch-off times
2 and 3 are entered in the same way -
please enter all values!
Symbols:
I ON = First switch-on time
(I OFF = first switch-off time)
20 °C = Set room temperature for
displayed heating time
Clock = Approximate program display
[full hours]
D
1 = Program for heating circuit 1
F
2
= Heating program 2,
F
1
= Heating program 1
D
I =
Start time 1, I
B
= Stop time 1,
D
II = Start time 2,
II
B
=
Stop time 2,
D
III = Start time 3,
III
B
= Stop time 3
21
Содержание E8.1121