2.4 Product data WKF/WKF-compact 120/180
Average condition
1)
Series
WKF 120
WKF-
compact
120
WKF 180
WKF-
compact
180
Energy efficiency ratio, heating 35°C/55°C
A+ / A+
A+ / A+
Energy efficiency ratio, hot water XL
A
A
Nominal heating power prated
kW
10,0
14,0
Room heating energy efficiency
h
s 35°C/55°C
%
147 / 118
146 / 122
Contribution to seasonal room heating energy
efficiency of the REMKO Smart Control
%
4
4
Yearly energy consumption Q
HE
35°C/55°C
4)
5514 / 6610
7860 / 9098
Hot water preparation energy efficiency
h
wH
%
102
107
Sound power level L
WA
(outdoor module)
dB(A)
67,9
68,3
Sound power level L
WA
(indoor module)
dB(A)
-
-
Warmer condition
2)
Series
WKF 120
WKF-
compact
120
WKF 180
WKF-
compact
180
Energy efficiency ratio, heating 35°C/55°C
A++ / A+
A+++ / A++
Energy efficiency ratio, hot water XL
A
A
Nominal heating power prated
kW
9,0
12,0
Room heating energy efficiency
h
s 35°C/55°C
%
165 / 123
180 / 143
Yearly energy consumption Q
HE
35°C/55°C
4)
2968 / 3354
3803 / 5349
Colder condition
3)
Series
WKF 120
WKF-
compact
120
WKF 180
WKF-
compact
180
Energy efficiency ratio, heating 35°C/55°C
A+ / A+
A+ / A+
Energy efficiency ratio, hot water XL
A
A
Nominal heating power prated
kW
12,0
18,0
Room heating energy efficiency
h
s 35°C/55°C
%
136 / 104
134 / 105
Yearly energy consumption Q
HE
35°C/55°C
4)
8481 / 12282
13300 / 17407
1)
Average condition = moderate temperature periods
2)
Warmer condition = warm temperature periods
3)
Colder condition = cold temperature periods
4)
The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit
13