REMKO WKF 120 compact Скачать руководство пользователя страница 5

1.6  Safety notes for the operator

The operational safety of the units and compo-

nents is only assured providing they are used as

intended and in a fully assembled state.

n

The units and components may only be set up,

installed and maintained by qualified per-

sonnel.

n

Protective covers (grille) over moving parts

must not be removed from units that are in

operation.

n

Do not operate units or components with

obvious defects or signs of damage.

n

Contact with certain unit parts or components

may lead to burns or injury.

n

The units and components must not be

exposed to any mechanical load, extreme

levels of humidity or extreme temperature.

n

Spaces in which refrigerant can leak sufficient

to load and vent. Otherwise there is danger of

suffocation.

n

All housing parts and device openings, e.g. air

inlets and outlets, must be free from foreign

objects, fluids or gases.

n

The units must be inspected by a service tech-

nician at least once annually. Visual inspec-

tions and cleaning may be performed by the

operator when the units are disconnected from

the mains.

1.7  Safety notes for installation,

maintenance and inspection

n

Appropriate hazard prevention measures must

be taken to prevent risks to people when per-

forming installation, repair, maintenance or

cleaning work on the units.

n

The setup, connection and operation of the

units and its components must be undertaken

in accordance with the usage and operating

conditions stipulated in this manual and comply

with all applicable regional regulations.

n

Local regulations and laws such as Water

Ecology Act must be observed.

n

The power supply should be adapted to the

requirements of the units.

n

Units may only be mounted at the points pro-

vided for this purpose at the factory. The units

may only be secured or mounted on stable

structures, walls or floors.

n

Mobile units must be set up securely on suit-

able surfaces and in an upright position. Sta-

tionary units must be permanently installed for

operation.

n

The units and components should not be oper-

ated in areas where there is a heightened risk

of damage. Observe the minimum clearances.

n

The units and components must be kept at an

adequate distance from flammable, explosive,

combustible, abrasive and dirty areas or

atmospheres.

n

Safety devices must not be altered or

bypassed.

1.8  Unauthorised modification

and changes

Modifications or changes to units and components

are not permitted and may cause malfunctions.

Safety devices may not be modified or bypassed.

Original replacement parts and accessories

authorised by the manufactured ensure safety. The

use of other parts may invalidate liability for

resulting consequences.

1.9  Intended use

Depending on the model, the equipment and the

additional fittings with which it is equipped is only

intended to be used as an air-conditioner for the

purpose of cooling or heating the air in an

enclosed room.

Any different or additional use shall be classed as

non-intended use. The manufacturer/supplier

assumes no liability for damages arising from such

use. The user bears the sole risk in such cases.

Intended use also includes working in accordance

with the operating and installation instructions and

complying with the maintenance requirements.

Under no circumstances should the threshold

values specified in the technical data be exceeded.

1.10  Warranty

For warranty claims to be considered, it is essential

that the ordering party or its representative com-

plete and return the "certificate of warranty" to

REMKO GmbH & Co. KG at the time when the

units are purchased and commissioned.

The warranty conditions are detailed in the "Gen-

eral business and delivery conditions". Further-

more, only the parties to a contract can conclude

special agreements beyond these conditions. In

this case, contact your contractual partner in the

first instance.

 

 

 

 

 

5

Содержание WKF 120 compact

Страница 1: ...Assembly instructions Read the instructions prior to performing any task REMKO WKF compact Inverter heat pump Installation instructions for the technician 0050 2016 06 Edition 1 en_GB ...

Страница 2: ...ad these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No liability accepted for errors or mis prints ...

Страница 3: ...otes 4 1 5 Safety conscious working 4 1 6 Safety notes for the operator 5 1 7 Safety notes for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Environmental protection and recycling 6 1 12 Transport and packaging 6 2 Installing the heat pump 7 3 Unit dimensions for indoor unit 13 4 Spare parts 15 5 Index 16 3 ...

Страница 4: ...be fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may cause injury or mate rial and environmental damage NOTICE This combination of symbol and signal ...

Страница 5: ...ls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary units must be permanently installed for operation n The units and components should not be oper ated in areas where there is a heightened risk of damage Observe the minimum clearances n The units and components must be kept at an adequate distance from flammable explosive combustible ab...

Страница 6: ... not dis posed in household waste but only in accordance with local regulations and in an environmentally safe manner e g using certified firms and recy cling specialists or at collection points 1 12 Transport and packaging The devices are supplied in a sturdy shipping con tainer or inside the heat pump casing Please check the equipment immediately upon delivery and note any damage or missing part...

Страница 7: ...door unit properly in the installation space refer to and carry out the following steps 1 Place the indoor unit and the storage tank as close to each other as possible in the instal lation space Fig 1 Fig 1 Heat pump in delivery state 2 Cut the straps and remove the box and pro tective film Check the indoor units for damage Fig 2 Fig 2 Remove the boxes and the film and check for damage 7 ...

Страница 8: ... and right side If necessary loosen the screws by 1 2 turns Fig 4 Fig 4 Remove the sheet metal casing 5 Remove the rear casing frame from the storage tank In the installation space level the storage tank using the adjustment feet Fig 5 Fig 5 Remove the casing frame 6 Screw the numbered corrugated pipes that are included in the delivery into the connec tions that are numbered accordingly on the sto...

Страница 9: ...he box of accessories EDP 260008 If the storage tank is still to be operated via a solar plant the lower storage tank probe must also be installed Fig 8 Installation of the immersion probe 8 Unpack the top part of the WKF and place it on a suitable surface Fig 9 Unpacking WKF compact top part 1 Fig 10 Unpacking WKF compact top part 2 9 Remove the front cover Fig 11 Remove front cover 9 ...

Страница 10: ...til it is optimally integrated completely into the bottom part of the EPP Now connect the two rear corrugated pipes to the two free connections Closed using a cap in the factory IL HP connection to changeover valve Fig 15 RF HP connection behind the changeover valve NOTICE Use the seals included in the box of accessories A B Fig 14 Install the indoor unit on the storage tank Fig 15 Connecting inle...

Страница 11: ...f the storage tank on the front left Fig 20 A and install them upwards through the openings provided for them in the casing cover Fig 20 B Circulation 4 HW outlet 3 CW inlet 5 Use seals If the connection is not used for a circulation it must be properly sealed to the storage tank directly A B 2 1 4 3 Fig 20 Domestic water connection 1 Hot water outlet 2 Circulation 3 Drain valve 4 Cold water inlet...

Страница 12: ...s the front sheet Fix the operating unit by also inserting the frame into the opening as far as the Con troller Fig 24 Indoor unit with operating unit 19 After successfully installing the Indoor unit of the WKF compact heat pump the entire system must be stamped in accordance with the DIN standard During installation ensure that the dirt trap that is included in the delivery is installed in the re...

Страница 13: ...or indoor units WKF compact Pipe connection arrangement A B 8 2 1 0 1 2 8 8 2 8 2 3 0 3 1 5 3 2 7 8 135 205 142 212 368 384 465 508 50 578 50 267 135 142 212 205 267 368 134 50 164 50 134 50 164 50 384 465 508 50 578 50 7 8 8 2 1 0 1 2 8 8 2 8 2 3 6 5 5 0 2 6 5 3 2 0 3 1 Fig 26 Pipe connection arrangement A WKF B WKF compact 13 ...

Страница 14: ...ections A WKF B WKF compact 1 Hot water 2 Circulation 3 Cold water supply 4 Heating inlet 5 Heating return flow 6 Refrigerant liquid pipe 3 8 7 Refrigerant heat gas pipe 5 8 8 2 Heat generator return flow heat pump outlet 9 Safety assembly 10 2 Heat generator inlet heat pump inlet 11 Solar connections REMKO WKF compact 14 ...

Страница 15: ...top 1250mm 259050 3 Corrugated tube 4 circ connection on middle 1600mm 259050 4 Corrugated tube 5 KW connection on bottom 2400mm 259050 5 1 x flat gasket for the 3 way valve outside 39mm x inside 27mm x thickness 2mm Material AFM 34 259050 6 10 x flat gasket for the corrugated tubes outside 30mm x inside 21mm x thickness 2mm Material AFM 34 259050 7 When ordering spare parts please state the compu...

Страница 16: ...tions 14 Pipe outlets on indoor unit spacing 13 S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Notes for inspection 5 Notes for installation 5 Notes for maintenance 5 Personnel qualifications 4 Safety notes for the operator 5 Safety conscious working 4 Unauthorised modification 5 Unauthorised replacement part manufacture 5 Spare parts 15 W Warranty 5 ...

Страница 17: ...17 ...

Страница 18: ...REMKO WKF compact 18 ...

Страница 19: ......

Страница 20: ...ct as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is quickly at the scene Our comprehensive network of experienced dealers always guarantees quick and reliable service REMKO INTERNATIONAL and also right in your neighbourhood Make use of our experience a...

Отзывы: