REMKO Wi-Fi stick Smart-Control Скачать руководство пользователя страница 5

1.6  Safety notes for the operator

The operational safety of the units and compo-

nents is only assured providing they are used as

intended and in a fully assembled state.

n

The units and components may only be set up,

installed and maintained by qualified per-

sonnel.

n

Protective covers (grille) over moving parts

must not be removed from units that are in

operation.

n

Do not operate units or components with

obvious defects or signs of damage.

n

Contact with certain unit parts or components

may lead to burns or injury.

n

The units and components must not be

exposed to any mechanical load, extreme

levels of humidity or extreme temperature.

n

Spaces in which refrigerant can leak sufficient

to load and vent. Otherwise there is danger of

suffocation.

n

All housing parts and device openings, e.g. air

inlets and outlets, must be free from foreign

objects, fluids or gases.

n

The units must be inspected by a service tech-

nician at least once annually. Visual inspec-

tions and cleaning may be performed by the

operator when the units are disconnected from

the mains.

1.7  Safety notes for installation,

maintenance and inspection

n

Appropriate hazard prevention measures must

be taken to prevent risks to people when per-

forming installation, repair, maintenance or

cleaning work on the units.

n

The setup, connection and operation of the

units and its components must be undertaken

in accordance with the usage and operating

conditions stipulated in this manual and comply

with all applicable regional regulations.

n

Local regulations and laws such as Water

Ecology Act must be observed.

n

The power supply should be adapted to the

requirements of the units.

n

Units may only be mounted at the points pro-

vided for this purpose at the factory. The units

may only be secured or mounted on stable

structures, walls or floors.

n

Mobile units must be set up securely on suit-

able surfaces and in an upright position. Sta-

tionary units must be permanently installed for

operation.

n

The units and components should not be oper-

ated in areas where there is a heightened risk

of damage. Observe the minimum clearances.

n

The units and components must be kept at an

adequate distance from flammable, explosive,

combustible, abrasive and dirty areas or

atmospheres.

n

Safety devices must not be altered or

bypassed.

1.8  Unauthorised modification

and changes

Modifications or changes to units and components

are not permitted and may cause malfunctions.

Safety devices may not be modified or bypassed.

Original replacement parts and accessories

authorised by the manufactured ensure safety. The

use of other parts may invalidate liability for

resulting consequences.

1.9  Intended use

The Wi-Fi stick is used to operate indoor units from

a remote location.

Any different or additional use shall be classed as

non-intended use. The manufacturer/supplier

assumes no liability for damages arising from non-

intended use. The user bears the sole risk in such

cases. Intended use also includes working in

accordance with the operating and installation

instructions and complying with the maintenance

requirements.

The threshold values specified in the technical

data must not be exceeded.

1.10  Warranty

For warranty claims to be considered, it is essential

that the ordering party or its representative com-

plete and return the "certificate of warranty" to

REMKO GmbH & Co. KG at the time when the

units are purchased and commissioned.

The warranty conditions are detailed in the "Gen-

eral business and delivery conditions". Further-

more, only the parties to a contract can conclude

special agreements beyond these conditions. In

this case, contact your contractual partner in the

first instance.

 

 

 

 

 

5

Содержание Wi-Fi stick Smart-Control

Страница 1: ...g and installation instructions Read the instructions prior to performing any task REMKO Wi Fi stick Smart Control For the room air conditioner series SKW RVT ATY ML MXW 0293 2021 06 Edition 1 en_GB RVD and RXT ...

Страница 2: ...erating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No liability accepted for errors or mis prints ...

Страница 3: ...ety notes for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transportation and packaging 6 1 12 Environmental protection and recycling 6 2 Technical data and scope of delivery 7 2 1 Technical data 7 2 2 Scope of delivery 7 3 Operation 8 3 1 General operation 8 3 2 Connection via WPS 9 3 3 Access via the REMKO Smart Con...

Страница 4: ...l or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may cause injury or mate rial and environmental damage NOTICE This combination of symbol and signal word wa...

Страница 5: ... factory The units may only be secured or mounted on stable structures walls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary units must be permanently installed for operation n The units and components should not be oper ated in areas where there is a heightened risk of damage Observe the minimum clearances n The units and components mu...

Страница 6: ...ection and recycling Disposal of packaging All products are packed for transport in environ mentally friendly materials Make a valuable contri bution to reducing waste and sustaining raw mate rials Only dispose of packaging at approved collection points Disposal of equipment and components Only recyclable materials are used in the manufac ture of the devices and components Help protect the environ...

Страница 7: ...it 1613234 ML 265 685 DC up to 08 2021 MXW 204 524 up to 08 2021 Wi Fi kit 1613236 RVD 355 525 DC RXT 525 1405 DC MXD 204 524 DC Wi Fi kit 1613239 RVD 685 1055 DC We reserve the right to make technical changes for the purpose of technical advancement 2 2 Scope of delivery Scope of delivery EDP no Description Wi Fi stick 1613235 Wi Fi stick QR Code activation code Wi Fi retrofit kit 1613234 Wi Fi s...

Страница 8: ...is ready for operation Flashing Reset restart executed Yellow Flashing No WLAN SSID network designation and WLAN password specified Wi Fi stick is in WPS mode and can receive WPS information from the router Magenta Flashing WLAN SSID network name and WLAN password are specified but no connection to the router can be established check the specified WLAN data Red Flashing WLAN SSID network designati...

Страница 9: ... the Wi Fi stick is in WPS mode the LED flashes yellow Press and hold 14 seconds No action is performed the LED lights up for 5 minutes and indi cates the status 3 2 Connection via WPS If the Wi Fi stick is in WPS mode LED flashes yellow the WPS button can be pressed on the router to establish a connection between the router and the Wi Fi stick Alternatively the WLAN data can also be stored when s...

Страница 10: ...ocket in its original position and fix it with the screw 6 Close the unit cover RVT 1 Disconnect the system from the power supply 2 Open the unit cover 3 Loosen the screw on the socket of the dis play board and remove the display board from the unit trim 4 Insert the Wi Fi stick into the designated interface 5 Place the display board including the socket in its original position and fix it with th...

Страница 11: ...he interface board which is attached to the left hand side of the rear panel The installation can be carried out as fol lows 1 Disconnect the system from the power supply 2 Open the unit cover 3 Loosen the screw on the socket of the inter face board and remove the interface board from the unit trim 4 Shorten the interface board at the predeter mined breaking point 5 Attach the remaining part of th...

Страница 12: ...he display board at the protrusion provided 4 Remove the adapter board plug from contact CN3 Then plug the connector of the Wi Fi interface board onto the now free contact CN3 and reattach the display board with the holder to the panel 5 Loosen the Phillips screw and remove the adapter board 6 Shorten the interface board at the predeter mined breaking point 7 Attach the remaining part of the inter...

Страница 13: ... board cover 4 Plug the adapter cable onto contact CN40 5 Insert the extension cable through the cable gland of the ceiling cassette and connect it to the adapter cable 6 Remove the bracket from the SmartPort with a slotted screwdriver and fix it to the wall or ceiling near the unit 7 Insert the Wi Fi stick into the interface of the SmartPort 8 Connect the extension cable to the Smart Port cable a...

Страница 14: ...ver 7 Close the unit cover RXT The Wi Fi stick is inserted into the interface of the Wi Fi SmartPort The SmartPort is connected to the control board The installation can be carried out as follows 1 Disconnect the system from the power supply 2 Open the filter grids and fold them down 3 Remove the control board cover 4 Plug the adapter cable onto contact CN49 5 Insert the extension cable into the c...

Страница 15: ...nsion cable to the Smart Port cable and attach the SmartPort to the bracket 9 Set the rotary switch S1 to 0 and the two switches of the DIP switch S2 to OFF 10 Replace the control board cover 11 Close the filter grids 15 ...

Страница 16: ... 685 DC from 07 2021 ATY 356 DC RVT 265 355 DC RVD 355 525 DC RVD 685 1055 DC RXT 525 1405 DC Singlesplit continued Unit series Swing function Fan level Anti freeze pro tection function SKW 261 521 DC from 2021 ML 265 685 DC up to 07 2021 ML 265 685 DC from 07 2021 ATY 356 DC RVT 265 355 DC RVD 355 525 DC RVD 685 1055 DC RXT 525 1405 DC See next page for an overview of the Multisplit unit function...

Страница 17: ...ting Temperature Adjusting MXW 204 524 up to 07 2021 MXW 204 524 from 07 2021 MXD 204 524 ATY 356 Multisplit continued Unit series Swing function Fan level Anti freeze pro tection function MXW 204 524 up to 07 2021 MXW 204 524 from 07 2021 MXD 204 524 ATY 356 17 ...

Страница 18: ...S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Notes for inspection 5 Notes for installation 5 Notes for maintenance 5 Personnel qualifications 4 Safety notes for the operator 5 Safety conscious working 4 Unauthorised modification 5 Unauthorised replacement part manufacture 5 Scope of delivery 7 T Technical data 7 U Unit data 7 W Warranty 5 WPS connec...

Страница 19: ......

Страница 20: ...0 5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und Wärmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 We reserve the right to make technical changes and provide no guarantee as to the accuracy of this data ...

Отзывы: