5.4 Activate heating and cooling
cycle, examples
Example for activating a heating circuit
1. Retrospective enabling of a heating circuit.
Activation of further heating circuits is only possible
in the expert level. To do so, activate the expert
level with the password "0321" and select the fol-
lowing parameters:
Expert level
¯
Settings
¯
Basic settings
¯
System configuration
In the "System configuration" level, set the required
heating circuit from "deactivated" to "activated".
After activation, the circuit is now enabled and can
be set in the "User" level and in the "Expert" level
of the connected heating circuit configuration. For
this purpose, implement the changes as described
in the chapter "Setting the heating/cooling oper-
ating mode".
¯
System configuration
¯
Deactivated
Activated
The REMKO Smart-Control Touch controller
can control max. one unmixed and four mixed
heating circuits!
Example for activating a cooling function
Change operating mode of a heating/cooling cir-
cuit.
The operating mode
n
Heating
n
Cooling
n
Heating/cooling
can be changed at any time in the respective acti-
vated heating circuits under the parameter "Oper-
ating mode".
User level
Expert level
¯
Settings
¯
Basic settings
¯
e.g. unmixed cycle
¯
Operating mode
¯
Heating
Cooling
Heating & cooling
REMKO Smart-Control Touch
88