3.2  External access via REMKO

Smart Web

If there is a stable network connection between the

router and the Smart Control Touch, it is possible

with the REMKO Smart Web interface to mirror the

display of the Smart Control Touch to a terminal

device via the Internet.

Fig. 10: External access

Registering on the Smart Web portal

http://smartweb.remko.media

Fig. 11: QR code for registration

The Smart Web portal is called up by entering the

address in the web browser.

(EN: 

Login

)

(EN: Register 

and get access to the 

REMKO Smart Web Portal

)

(EN: Password)

(EN: 

Register

)

(EN: 

*Mandatory fields

)

Fig. 12: Smart Web portal login

A login is now required on the Smart Web portal. If

no user account has been created yet, it is pos-

sible to select the "Register" button and create a

user account. Once the registration form has been

completed and sent, a confirmation link will be sent

to the e-mail address provided. By clicking on the

link contained in the message, the user account is

confirmed and the registration is completed. You

can now login with the activated user account.

Adding devices to the Smart Web portal

(EN: Add unit)

Fig. 13: Add unit

To add a new or first unit, press the "Add unit"

button.

 

 

 

REMKO Smart-Control Touch

 

 

12

Содержание ML 264-525 DC

Страница 1: ...tion instructions Read the instructions prior to performing any task REMKO Smart Control Touch For the room air conditioner series ML MVV MXD MXW 0229 2019 07 Edition 1 en_GB Manual for experienced sp...

Страница 2: ...rating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No li...

Страница 3: ...maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transportation and packaging 6 1 12 Environmental protection and recycling 6 2 Technica...

Страница 4: ...tal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combina...

Страница 5: ...ose at the factory The units may only be secured or mounted on stable structures walls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary uni...

Страница 6: ...otection and recycling Disposal of packaging All products are packed for transport in environ mentally friendly materials Make a valuable contri bution to reducing waste and sustaining raw mate rials...

Страница 7: ...lative non condensing Remote control EDP no 248104 WLAN stick EDP no 1121589 We reserve the right to make technical changes for the purpose of technical advancement 2 2 Unit dimensions 151 151 80 24 1...

Страница 8: ...at the bottom of the screen This enables fast and intuitive navigation through the basic menus 1 Overview Fig 4 Overview The overview display shows information such as the date and time the current o...

Страница 9: ...the indi vidual points is carried out with the aid of the arrow symbols which appear at the bottom of the screen as soon as an input is possible 5 Reserved Defining the higher level operating mode Fi...

Страница 10: ...t temperature in 1 steps Temperatures between 17 C and 30 C can be selected 4 Fan speed Determine the fan speed of the indoor unit It is possible to choose between Low Medium High and Automatic 5 Swin...

Страница 11: ...n JavaScript HTML5 capable web browser Edi tion not more than two years old n Broadband internet connection of at least 10 mbit s n The WLAN router must support the WPA 2 encryption security standard...

Страница 12: ...to the REMKO Smart Web Portal EN Password EN Register EN Mandatory fields Fig 12 Smart Web portal login A login is now required on the Smart Web portal If no user account has been created yet it is po...

Страница 13: ...door unit can be read from the name plate of the outdoor unit which is usually located near the cover for the electrical wiring 3 Activation code The activation code is displayed on the Smart Con trol...

Страница 14: ...tions to be used that are also directly available on the control unit 2 User In this window additional users can be added to operate the controller and access to the REMKO service limited to 1 hour ca...

Страница 15: ...long holes provided Then establish the electrical wiring connection as described in the chapter Electrical connection 5 Place the mounting plate together with the electronics in the surface mounted ho...

Страница 16: ...unted installation a double socket with the following dimensions must be provided at the desired installation position Fig 17 Double socket A 12V direct current source is required for the flush mounte...

Страница 17: ...t the back of the touch display by pulling it up and remove the ribbon cable 3 Remove the four marked Phillips screws and then pull the mounting plate together with the electronics out of the surface...

Страница 18: ...the surface mounted housing using the four marked Phillips screws 6 Plug the ribbon cable with the blue marking upwards into the terminal block at the back of the display and fix it with the grey lev...

Страница 19: ...llation the trans former included in the scope of delivery is used for the power supply 230V 12V If the unit is flush mounted a 12V direct current source must be provided at the installation position...

Страница 20: ...120 W resistor must also be provided on the last indoor unit and on the MVV outdoor parts Further information on the connections can be found in the operating instructions of the respective devices A...

Страница 21: ...Y E A B GND 12V 120 Fig 20 Multi split system connection 1 Router 2 WiFi 3 Network cable 4 Smart Control Touch 5 Indoor unit 1 6 Indoor unit 2 3 4 7 Flush mounted power supply unit or power supply un...

Страница 22: ...1 2 3 4 5 6 Fig 21 VRF system connection 1 Router 2 WiFi 3 Network cable 4 Smart Control Touch 5 Outdoor unit type MVV DC 6 Flush mounted power supply unit or power supply unit with Euro plug REMKO S...

Страница 23: ...ess 0 8 4 1 2 3 5 6 7 C 9 A B D E F ON 1 2 0 15 0 8 4 1 2 3 5 6 7 C 9 A B D E F ON 1 2 16 31 0 8 4 1 2 3 5 6 7 C 9 A B D E F ON 1 2 32 47 0 8 4 1 2 3 5 6 7 C 9 A B D E F ON 1 2 48 63 VRF indoor units...

Страница 24: ...ation 11 O Operation 8 S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Notes for inspection 5 Notes for installation 5 Notes for maintenance 5 Personnel q...

Страница 25: ...25...

Страница 26: ...REMKO Smart Control Touch 26...

Страница 27: ......

Страница 28: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Отзывы: