6
Emergency-heat
operation
If the compressor fails, you can start emergency-
heat operation as follows:
1.
Activation of emergency-heat operation is
only possible in the expert level of the Smart-
Control regulation. To do this, select the
"Expert" level on the basic display.
2.
After activating the expert level by touching
the REMKO logo, a password is required (the
password is: "0321").
3.
After confirmation, +/- symbols are displayed
at the bottom. The password can be set by
touching the +/- symbols. After the entry,
confirm with "OK".
The REMKO default password for the expert
level is "0321". If this password has not
already been changed, the expert level is
enabled after entering this password.
After the expert level has been enabled, var-
ious parameter levels are visible.
4.
Select the "Settings" level by touching the
"Settings" icon.
5.
After selecting the "Settings" level, select the
"Basic settings" parameter.
6.
The "System configuration" parameter
appears in the "Basic settings" level. Select
this icon by touching it.
7.
After selecting the "System configuration"
level, select the "Heat pump" parameter.
8.
Then deactivate the heat pump in the “Heat
pump” level by touching the “activated” icon
and changing the operating mode setting
from “activated” to “deactivated”.
The heat pump is now deactivated.
With deactivation of the heat pump, the second
heat generator, e.g. the REMKO Smart-Serv auxil-
iary heater or a condensing unit installed in the
system is active.
NOTICE!
If the heat pump is switched off, e.g. by trig-
gering the fuse, the water must be drained
manually to prevent freezing.
REMKO LWM series
46
Содержание LWM 110
Страница 62: ...REMKO LWM series 62 ...
Страница 63: ......