7
Condensate removal
Depending on the air temperature and the relative
humidity, condensed water will drip into the con-
densate container either continuously or only
during the defrosting phases.
A float is located inside the condensate container.
In the event that the container is full, the float will
activate a water stop switch which will switch off
dehumidification mode.
To guard against accidental stops caused by water
sloshing around etc., this switch does not activate
until after a time delay of 10 seconds. The unit will
switch off and the red "TANK FULL" indicator light
on the control panel will flash.
In order to empty the condensate tank, proceed as
follows:
1.
Actuate the "ON/OFF" switch.
2.
Remove the filled condensate tank. To do
this, lift the container slightly using the
embedded recessed grip and then pull it
carefully forwards and out.
NOTICE!
Beware of dripping condensate. After switching
off the units, the evaporator may continue to
defrost under the influence of the ambient tem-
perature.
3.
Place the container carefully outside the unit
and pull of the sealing cover [A] of the
pouring opening [B].
A
B
4.
Pour the water into a drain.
5.
Close the pouring opening [B] and carefully
insert the condensate container back into the
unit.
6.
NOTICE!
After being emptied, the condensate con-
tainer incl. float must be checked for
damage, contamination etc.
Switch the unit on again with the "ON/OFF"
key .
NOTICE!
The units are only fully functional if the conden-
sate container is inserted properly.
Unit operation with hose connection
The hose connection is implemented directly on
the 12 mm
Ø
screw-in hose nozzle that is placed
on the top edge of the condensate tank when
shipped.
Connect the hose as follows:
1.
Remove the condensate tank.
2.
Remove the screw-in hose nozzle from the
place-holder [D] and swap this for the sealing
screw in the 3/8" inside thread [C]. Then
tighten the screw-in hose nozzle hand-tight.
Ensure that the connection is sealed!
3.
Plug hose with inside diameter 12 mm onto
the screw-in hose nozzle and secure this with
a hose clamp to prevent it slipping off.
4.
Then fit the condensate tank back into place.
Ensure that there are no kinks in the hose!
21