Commissioning
Before commissioning the unit or if local require-
ments dictate, the air-inlet grille and air-outlet grille
must be checked for contamination.
NOTICE!
A contaminated grille or filter must be cleaned
or replaced immediately.
Important notes prior to commissioning
n
All extensions to the electrical connection must
be of a sufficient cable size and must only be
used fully rolled out or unrolled.
n
Never use the power supply connection cable
as a pull cord.
n
After being switched on, the units operate fully-
automatically until switched off by the float
when the condensate container is full.
n
The condensate container must be inserted
properly.
n
In order to prevent damage to the condenser,
the units are equipped with a mechanism that
prevents the compressor from being immedi-
ately switched back on after it is switched off
The compressor does not switch back on
until after a waiting time of ca. 1 minute!
NOTICE!
In room temperatures below
10 °C
and relative
humidity below
40%
, economical use of the unit
can no longer be guaranteed.
Starting the unit
Start the unit as follows:
1.
Plug the unit's power plug into a properly
installed and fused mains socket (230V/50
Hz).
If you connect the dehumidifier to the mains,
the unit should be switched off (not oper-
ating). The segment display and LED indica-
tors illuminate for 3 seconds (the humidity
display shows "88" and the hour counter dis-
play shows "88888.8"). After that the seg-
ment display for the humidity [3] shows the
environmental humidity and the display for
the operating hours counter and the energy
counter [6] shows the operating hours
counted for the compressor.
2.
Actuate the "ON/OFF" key.
The green "COMP. ON" indicator light illumi-
nates. The unit switches on with a time delay
of around 10 seconds and then runs in con-
tinuous operating mode.
The unit will now operates fully-automatically
until the desired relative humidity (% RH) has
been reached or until the unit is switched off
by the float when the condensate container is
full. In this case, the red "FULL TANK" indi-
cator light illuminates.
Automatic restart after power failure:
If the electrical power fails or if the power plug is
pulled out during operation, the unit switches off.
When the unit is switched back on again or if the
power plug is put back in again the unit starts up
again automatically after a safety delay time of 70
seconds.
REMKO LTE
16