7
Troubleshooting and
customer service
DANGER!
Vor allen Arbeiten an den Geräten muss der
Netzstecker aus der Netzsteckdose gezogen
werden.
Reparaturen bzw. Änderungen an der Elektroin-
stallation sowie der Zuleitung dürfen aus sicher-
heitstechnischen Gründen ausschließlich durch
autorisiertes Fachpersonal ausgeführt werden.
The unit has been manufactured using state-of-
the-art production methods and has been tested
several times to ensure that it works properly. How-
ever, in the event that malfunctions should occur,
the unit should be checked against the following
list. Please inform your dealer if the unit is still not
working correctly after all of the functional checks
have been performed.
The unit (fan) does not start
1.
Check the mains fuses provided by the cus-
tomer.
2.
Check the power plug.
3.
Check the operating switch.
4.
Check that the fan can move freely.
The unit does not heat up
1.
Check the operating switch.
2.
Check that the contactor is functioning cor-
rectly.
3.
Check that the thermal cut-out or capillary
tube are functioning correctly and check for
damage.
4.
Check whether the thermostat or strapping
plug are plugged in.
5.
In case of unit operation with a room thermo-
stat, set the thermostat to a value that is
higher than the room temperature.
REMKO ELT series
12