Edition GB – U01
REMKO ATY
ATY 261, ATY 351
Wall-mounted air conditioning unit
Operation · Technology · Spare parts
Страница 1: ...Edition GB U01 REMKO ATY ATY 261 ATY 351 Wall mounted air conditioning unit Operation Technology Spare parts...
Страница 2: ......
Страница 3: ...onmental protection and recycling 4 Warranty 4 Transportation and packaging 5 Description of the equipment 5 Combinations 5 Operation 6 13 Shutdown 14 Care and maintenance 14 15 Troubleshooting and cu...
Страница 4: ...kept a safe distance from inflammable explosive combustible agressive and dirty areas or atmospheres Persons coming into contact with equipment parts may suffer burns or injury Installation repair an...
Страница 5: ...infrared remote control The indoor unit comprises a finned vaporiser vaporiser fan controller and condensation tray The indoor unit may be used in conjunction with REMKO outdoor components that provi...
Страница 6: ...shooting and customer service CAUTION Infrared remote control Immediately replace flat batteries with a new set otherwise there is a risk of leakage It is recommended that the batteries are removed i...
Страница 7: ...ode the room air is circulated 5 Dehumidifying mode In this mode the room is mainly dehumidified the set temperature is maintained FAN Button Press this button to set the required fan speed 4 levels a...
Страница 8: ...nly supported in cooling mode In automatic mode press the button to reduce the fixed temperature from 24 C by 1 or 2 C press the button to increase it by 1 or 2 C The current setting is displayed next...
Страница 9: ...room air If the actual temperature falls approx 0 5 C below the set room temperature the controller switches the cooling off In order to protect the compressor the controller will only switch the coo...
Страница 10: ...function The swing function improves air circulation in the room SWING Button hidden SWING SWING SWING Press this button to set the fan speed One can choose between low medium high and automatic fan s...
Страница 11: ...ch on switch off timer The switch on off time will flash The Timer symbol on the indoor unit is lit Press the and buttons to set the desired switch on off time If set successfully the Timer symbol wil...
Страница 12: ...tching off the unitPress several times to set the timer to 30 minutes 1 hour 2 hours 3 hours or 5 hours The current time is replaced by the remaining time OFF OFF OFF Press this button to increase the...
Страница 13: ...temperature remains unchanged DISP Button hidden DISP C C The unit includes an ion generator for generating negative ions High levels of negative ions may be found in mountain regions near waterfalls...
Страница 14: ...ing a damp cloth Do not use any caustic abrasive or solvent based cleaning products Do not use a jet of water Clean the fins on the unit prior to long shutdown periods Maintenance It is recommended th...
Страница 15: ...manual 1 Open front cover 5 Cleaning with lukewarm water 3 Press up the flaps on the filter and pull it down and out by the flaps Fig 3 4 Clean the filter using a normal vacuum cleaner The dirty side...
Страница 16: ...he receiver or transmitter unit in the shade Electromagnetic fields are interfering with transmission Does it function when switching off possible sources of interference Signal is not transmitted whe...
Страница 17: ...0 proceed to step 5 4 If digit I is 1 press the Programming E7 Digit I Digit II Digit III Digit IV Digit V Digit VI is displayed before continuing with the programming procedure 10 Point the transmit...
Страница 18: ...frigerant pipes injection and suction pipe valves and connections to make them tight against vapour diffusion If necessary also insulate the condensation pipe Select an installation location which all...
Страница 19: ...board Fig 9 5 If necessary remove the break outs on the housing 6 Fit the unit to the wall 7 Connect the refrigerant pipes electrical cables and condensation pipe to the indoor unit as described belo...
Страница 20: ...directly into a sewer pipe fit a trap to prevent any unpleasant odours When operating the unit at outdoor temperatures below 0 C ensure the condensation pipe is laid to protect it against frost If nec...
Страница 21: ...junction with the unit it may be necessary to install an additional relay with a higher contact rating after the switch off contact on the pump to switch off the compressor Connecting the indoor unit...
Страница 22: ...motor Front 2 CN 6 CN 8 CN 9 CN 10 CN 11 CN 1 CN 4 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 1 2 3 N2 1N 2 3 4 5 CN...
Страница 23: ...rt and check the safety functions 4 Check the indoor unit control system using the functions described in the chapter Operation Timer temperature setting fan speeds and switching to ventilation or deh...
Страница 24: ...view ATY 261 ATY 351 4 15 3 1 2 5 5 14 6 7 8 14 11 10 12 16 9 7 7 13 17 We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process REM...
Страница 25: ...motor set 1107404 1107404 6 Swing motor 1107405 1107405 7 Outlet fins set 1107406 1107406 8 Condensation tray 1107439 1107439 9 Finned vaporiser 1107408 1107409 10 Fan wheel vaporiser 1107410 1107410...
Страница 26: ...410 440 Noise output per stage 3 dB A 33 36 40 35 37 41 Voltage supply V Hz 230 1 50 Protection degree IP X0 Nom electrical power consumption cooling 1 kW 0 03 0 04 Nom current consumption cooling 1 A...
Страница 27: ...Notes...
Страница 28: ...ts in the areas of air conditioning and heating technology Customer service Our equipment is precise and reliable However should a fault should occur REMKO customer service is quickly at your side Our...