background image

19

REMINGTON iLIGHT Face and Body.

•   

DO NOT

 use REMINGTON iLIGHT Face 

and Body if your skin is sensitive to 

light.  In order to determine if you can 

use REMINGTON iLIGHT Face and 

Body, perform a test on a small patch 

of skin and wait 24 hours to determine 

if there are any adverse reactions 

before using REMINGTON iLIGHT Face 

and Body more broadly.  See steps for 

testing on a patch of skin on page 30.  

Contact Customer Service (page 50) for 

more information or assistance.

•   

DO NOT

 use REMINGTON iLIGHT Face 

and Body if you are or may be pregnant 

or are breast-feeding.  REMINGTON 

iLIGHT Face and Body has not been 

tested on pregnant women.  Hormonal 

changes are common during pregnancy 

or breast-feeding and could increase 

skin sensitivity and the risk of skin 

injury.

•  

DO NOT

 flash REMINGTON iLIGHT Face 

and Body against any material other 

than skin. 

•   

DO NOT

 use REMINGTON iLIGHT Face 

and Body for any purpose other than 

hair removal.  

•   

DO NOT

 use REMINGTON iLIGHT Face 

and Body on any area where you may 

someday want your hair to grow back.  

The results may be permanent and 

irreversible.

•   

DO NOT 

cover any part of the 

REMINGTON iLIGHT Face and Body 

ventilation slots during use, as they help 

to keep the device cool during opera-

tion.  Covering the ventilation slots could 

result in the REMINGTON iLIGHT Face 

and Body device overheating.

•  

DO NOT

 use REMINGTON iLIGHT Face 

and Body if the box packaging or the 

device appears damaged or if any part 

of the REMINGTON iLIGHT Face and 

Body body is cracked or broken.  Doing 

so could increase the risk of skin or 

eye injury from the flash lamp.  Contact 

Customer Service for assistance (page 

50).

Precautions

Содержание iLIGHT SP6000FUS

Страница 1: ...ister Your New Product Today By registering your new Remington product you will receive these important benefits Proof of Ownership Product Protection Product Registration Special Offers Register onli...

Страница 2: ...iLIGHT Face and Body 8 FacialLIGHT Cap 9 Changing Treatment Caps 10 Quick Reference Guide 12 What is REMINGTON iLIGHT Face and Body used for Indications 16 Who should not use REMINGTON iLIGHT Face an...

Страница 3: ...Test a Patch of Skin Step 5 Treat Your Skin Other Treatment Tips 37 After your REMINGTON iLIGHT Face and Body treatment Cleaning REMINGTON iLIGHT Face and Body Replacing the Lamp Cartridge DISPOSAL O...

Страница 4: ...mington iLIGHT Face and Body doesn t cut or pull out hair it actually uses light energy to work below the skin s surface to disable active hairs at the root You should gradually notice fewer hairs in...

Страница 5: ...Face and Body affects only hairs that are in the active growth phase Your initial regimen should be spread out over 1 month to ensure that you target the most number of active hairs including those t...

Страница 6: ...6 Figure 1 iLIGHT Face and Body System Diagram Reference...

Страница 7: ...ws you to control the energy level that s effective and comfortable for you see instructions for Testing the Remington iLIGHT Face and Body on a patch of skin on page 30 The Power Button is located ne...

Страница 8: ...he face See section Changing Treatment Caps for instructions on how to exchange caps FacialLIGHT Cap Each Sideburn Each Cheek Above lips Chin Neck Where you can use the FacialLIGHT Cap The FacialLIGHT...

Страница 9: ...are not to damage the FLASH WINDOW and other components 3 Gently push the other treatment cap back into the Hand Piece making sure both side tabs click into place NOTE the longer tab with gold circuit...

Страница 10: ...R UNSUITABLE skin BUZZ SUITABLE skin BEEP BEEP and the system will unlock You must unlock on each body part you intend to treat 3 SELECT ENERGY LEVEL see page 29 The REMINGTON iLIGHT Face and Body sys...

Страница 11: ...ash is delivered you will See a bright flash of light Hear a POP sound the disposable cartridge Feel a mild sensation of warmth and tingling LIFT the HAND PIECE off the skin and move it to a new treat...

Страница 12: ...to Medium Skin Tones below you can use REMINGTON iLIGHT Face and Body If your Skin Tone in the intended What Is Remington iLIGHT Face And Body Used For Indica treatment area matches the Dark Skin Ton...

Страница 13: ...y or white hairs or peach fuzz REMINGTON iLIGHT Face and Body will not work on LIGHTER HAIR PALE BEIGE BEIGE LIGHT BROWN MEDIUM BROWN DARK BROWN BLACK BROWN BLACK DARK BLOND LIGHT BLOND RED PEACH FUZZ...

Страница 14: ...llustration below lists the typical number of flashes needed to cover a 1 5 x 2 treatment area Treat in a GRID LIKE PATTERN slight overlaps are OK but DO NOT flash the same EXACT spot multiple times d...

Страница 15: ...llustration below lists the typical number of flashes to treat the entire site NOTE for spot treat ments of unwanted hair fewer flashes may be needed Record treatments in the TREATMENT CARDS on page 5...

Страница 16: ...your Skin Tone is suitable for use with REMINGTON iLIGHT Face and Body You should test each different area of skin you want to treat Some areas are darker than others DO NOT USE REMINGTON iLIGHT Face...

Страница 17: ...CH OF CHILDREN DO NOT leave REMINGTON iLIGHT Face and Body unattended around children as the cords represent a choking hazard Children should be supervised to ensure that they do not play with the app...

Страница 18: ...ean the intended treatment area before using REMINGTON iLIGHT Face and Body DO NOT flash REMINGTON iLIGHT Face and Body on the identical treatment spot multiple times during the same session as this c...

Страница 19: ...ease skin sensitivity and the risk of skin injury DO NOT flash REMINGTON iLIGHT Face and Body against any material other than skin DO NOT use REMINGTON iLIGHT Face and Body for any purpose other than...

Страница 20: ...TREATMENT CAP and or LAMP CARTRIDGE or attempt to repair your REMINGTON iLIGHT Face and Body as it contains no user serviceable parts Trying to open REMINGTON iLIGHT Face and Body may also damage the...

Страница 21: ...prevent the blister from becoming infected If you need more information contact Customer Service see page 50 In rare cases an outbreak of cold sores may develop in the area s treated that have a hist...

Страница 22: ...area has changed stop using REMINGTON iLIGHT Face and Body and contact Customer Service see page 50 Eye Injury Flashing any laser or IPL device near or around the eyes could cause serious and permane...

Страница 23: ...d Tingling It is normal to feel a warm and tingling sensation with each flash Many people describe this sensation to be like a rub ber band lightly snapped against the skin However sensations vary by...

Страница 24: ...nt schedule to ensure you hit all hairs in the growth phase in the tar geted area Two Weeks after the Last Treatment You should see a noticeable reduction in hairs in the treated area Also any new hai...

Страница 25: ...tch of skin See steps on page 30 In addition we recommend that you use REMINGTON iLIGHT Face and Body in a cooler area where the temperature is less than 80 F 27 C to help keep the device from overhea...

Страница 26: ...age REMINGTON iLIGHT Face and Body requires that you test your skin tone before every use Since some skin areas are darker than others test each differ ent area you want to treat DO NOT use REMINGTON...

Страница 27: ...n each body part you plan to treat 2a Turn the POWER SWITCH on The SKIN TONE SENSOR will flash YELLOW You will hear a series of audible BEEPS every 5 seconds to remind you to take the test For safety...

Страница 28: ...y for use 2d If your SkinTone is NOT suitable for use the SKINTONE SENSOR turns solid YELLOW and the device will BUZZ once for 5 seconds After 5 seconds you may re try the SKINTONE SENSOR step 1 above...

Страница 29: ...ERGY LEVEL Energy Level Indicator Lights determine the intensity of the REMINGTON iLIGHT Face and Body light flash delivered to your skin from the lowest level to the highest level Higher levels impro...

Страница 30: ...te Energy Level to use the first time you use the device or for each new treatment Energy Level 1 2 3 4 5 Press Energy Level Setting Button Defaults to Level 1 upon start up Energy Level Selection Dis...

Страница 31: ...ou feel more than moderate pain stop using REMINGTON iLIGHT Face and Body immediately and call Customer Service see page 50 for help If a flash delivered at Energy Level 1 feels tolerable press the EN...

Страница 32: ...l turn off when the REMINGTON iLIGHT Face and Body is ready to use again The number of flashes delivered before the cool down state depends on several factors including how fast you apply the treatmen...

Страница 33: ...with the skin 5d If the CONTACT SENSORS on the treatment cap are in full contact with the skin a series of high pitched BEEPS will sound indicating the device is OK to flash 5e Press the FLASH BUTTON...

Страница 34: ...on is kept depressed the hand piece can be slid between spots About 2 seconds later assuming Contact Sensors are in contact with skin the device will once again emit a BEEP to confirm that it is ready...

Страница 35: ...d Treatment Schedule Your initial regimen should be spread out over 1 month to ensure that you target the most number of active hairs including those that recently cycled from the resting phase We rec...

Страница 36: ...w well you shave will make a big difference in how the treat ment feels See page 25 Periodically if the device gets too hot the Hourglass icon will flash and the unit will beep Wait for a few minutes...

Страница 37: ...and Body After each session clean your REMINGTON iLIGHT Face and Body device especially the LIGHT WINDOW the CONTACT SENSORS and the SKIN TONE SENSOR window DO NOT place any part of the REMINGTON iLIG...

Страница 38: ...mage the FLASH WINDOW DO NOT attempt to open or repair your REMINGTON iLIGHT Face and Body device Only authorized REMINGTON iLIGHT Face and Body repair centers are permitted to perform repairs SENSORS...

Страница 39: ...e replaced Once all 30 000 flashes in a LAMP CARTRIDGE have been used the BULB LIFE LIGHT will flash yellow indicating that further flashes cannot be delivered In order to continue the hair removal se...

Страница 40: ...p the LAMP CARTRIDGE and gently pull away from the HAND PIECE Discard the used cartridge with normal household trash WARNING Ensure cartridge has cooled for 5 minutes before handling Exercise care whe...

Страница 41: ...on the right 5 Gently push the treatment cap back into the HAND PIECE making sure both sides click into place NOTE the lon ger tab with gold circuits must be on top to properly fit DISPOSAL OF REMINGT...

Страница 42: ...em isn t connected properly Make sure the power cord is properly con nected to the REMINGTON iLIGHT Face and Body device and that the power cord is plugged into an electrical outlet on the wall The ou...

Страница 43: ...unlock the REMINGTON iLIGHT Face and Body again to use it See steps on page 30 for Test a Patch of Skin using the Skin tone sensor The CONTACT SENSORS aren t in full contact with the skin Check that...

Страница 44: ...ver The REMINGTON iLIGHT Face and Body requires 5 seconds to recover between flashes When your REMINGTON iLIGHT Face and Body device is ready to flash and assuming the CONTACT SENSORS are flush agains...

Страница 45: ...n Wait for a few minutes for the REMINGTON iLIGHT Face and Body to cool down There is no need to shut the unit down as the hourglass icon and beeps will turn off when the REMINGTON iLIGHT Face and Bod...

Страница 46: ...NTACT SENSORS may be stuck Lift the HAND PIECE from the BASE UNIT and check the CONTACT SENSORS The CONTACT SENSORS should slightly protrude from the sides of the HAND PIECE window You should be able...

Страница 47: ...he treatment cap is properly attached you should hear a click and the lights and audible tones will stop I used the SKIN TONE SENSOR and it showed an YELLOW light I can t unlock the system Your skin i...

Страница 48: ...NGTON iLIGHT Face and Body device Only authorized REMINGTON iLIGHT Face and Body repair centers are permitted to perform repairs Opening REMINGTON iLIGHT Face and Body may expose you to dangerous elec...

Страница 49: ...ize 2 0cm2 2 25 for Body Cap 4 for FacialLIGHT Cap Xenon Flash Lamp IPL 8 J cm2 20 600 1200 nm 120VAC UL 60335 EN60335 10 125 x 9 625 x 8 3125 Labeling EC Declaration of Conformity Customer Service 80...

Страница 50: ...warranty does not include damage to the product result ing from accident or misuse If the product should become defec tive within the warranty period we will replace it free of charge Return your prod...

Страница 51: ...anded product you are not satisfied and would like a refund return it with the sales slip indicating purchase price and date of purchase to the retailer from whom it was purchased Spectrum Brands Inc...

Страница 52: ...Treatment Cards below to help keep track of your treatments Body Hair For a typical 1 5 x 2 treatment area you should use 10 flashes to fully treat that complete area Treat in an organized grid patter...

Страница 53: ...treatments on each area If you have redness blistering or other skin irritation in the treatment area DO NOT perform treatment Wait until the skin returns to normal before using REMINGTON iLIGHT Face...

Страница 54: ...54 Treatment Cards...

Страница 55: ...55...

Страница 56: ...56 Treatment Cards...

Отзывы: