4
The instructions on the circuit diagrams provided with the
appliance,
4
The manufacturer’s instructions.
Belgium
: The earthing must comply with the RGIE standard.
Germany
: The earth connection shall comply with standard
VDE 0100.
France
: The earth connection shall comply with standard
NFC 15-100.
Other countries
: The earthing shall comply with local standards.
CAUTION
4
Separate the sensor cables from the 230/400 V
circuit cables.
4
The installation must be fitted with a main switch.
The appliance is delivered pre-wired.
The electricity supply is connected to the mains by connection cable
(~230 V, 50 Hz) and electrical plug.
The electrical plug must be accessible at all times.
4.10.2.
Connecting the solar control system
DANGER
Do not expose the appliance to strong magnetic fields.
Keep the electrical connection cable separate from the
sensor cables.
CAUTION
It must be possible for the regulator to be isolated from the
mains by a circuit breaker that provides at least a 3 mm
gap between all the poles or by a circuit breaker that
conforms to installation standards.
1. Remove the insulating shell from the front of the solar station, if
necessary.
2. Remove the Phillips-head screws from the cover and detach it
from the box.
3. Make the electrical connection.
See electrical schematics.
4. Put the cover back in place and secure with the screws.
5. Put the insulating shell back in place if necessary.
4.10.3.
Electrical diagram
M002758-A
2
5
4. Installation
200SE-2S - 300SE-2S
34
26/04/2016 - 7607575-05
Содержание RemaSol200SE-2S
Страница 7: ...26 04 2016 7607575 05 5 ...
Страница 74: ...en Appendix Information on the ecodesign and energy labelling directives ...
Страница 77: ...1 Specific information 4 7607575 ErP02 21042016 ...