Caution
Do not connect a frost thermostat or room thermostat to the boiler
if using the 0–10 V PCB.
4.4
Control panel description
4.4.1
Description of the user interface
1 Rotary knob to select a menu or setting
2 Validation button
3 Back key to return to the previous level or previous menu
4 Main menu key
5 Display screen
6 LED for status indication:
continuous green = normal operation
flashing green = warning
continuous red = shutdown
flashing red = lockout
4.4.2
Description of the main screen
This screen is displayed automatically after the appliance is started up.
The screen goes into standby if no key is pressed for five minutes. Press
one of the buttons on the control panel to exit standby.
1 Symbols
The selected icon is highlighted.
2 Information on the selected icon
3 Navigation level:
: Chimney Sweep level
: User level
: Installer level
This level is reserved for installers and is protected by an access
code. When this level is active, the
Off
icon becomes
On
.
4
error notification: only visible if an error occurs.
Tab.1
Symbols
User Level
Maintenance message
Installer Level
Water pressure
Chimney Sweep level
Outdoor temperature sensor
Timer programme
Buffer tank
Timer programme override
Cascade
Holiday mode
Boiler
Manual mode
Burner output level
Eco mode
Burner on
Frost protection mode
Domestic hot water override
,
,
,
,
Zone icons
All zones
Fig.7
MW-5000756-1
3
4
1
2
5
6
Fig.8
29,4°C
29,6°C
51,2°C
6,7°C
21,8°C
29,4°C
1,8 bar
Not Set
None
off
OFF
OK
I
I
MW-5000763-2
2
4
3
1
4 Description of the product
16
MID _HMI T-control - Gas 120 ACE
7717201 - v03 - 25062019