background image

DCO-0599 

Effective Date: 14-DEC-2018 

 

LBL-6025 Rev B 

Page  6 of 8 

 

 

been subject to accident, negligence, alteration, abuse or misuse.  

Relign makes no warranty whatsoever with regard to accessories or 

parts used in conjunction with the Tricera Handpiece and not supplied 

and manufactured by Relign. 
No agent, employee, or representative of Relign or its affiliates has any 

authority to change any of the foregoing or assume or bind Relign or 

any of its affiliates to any additional liability or responsibility in 

connection with this device.  The essential purpose of this provision is 

to limit the potential liability of Relign and its affiliates arising out of this 

agreement and/or any purchase and sale hereunder.  Original 

purchaser shall be responsible for ongoing equipment support and 

maintenance not covered by this warranty and after the warranty period 

has expired. 
The term “original purchaser,” as used in this warranty means that 

person or organization and its employees, if applicable, to whom the 

Tricera Handpiece was sold by Relign.  This warranty may not be 

assigned or transferred in any manner. 
In order to make a warranty claim, the original customer must obtain a 

Return Materials Authorization Number (“RMA Number”) and return 

instructions from Relign’s Customer Service Department or authorized 

representative.  The allegedly defective Tricera Handpiece must be 

returned, cleaned, repackaged, clearly marked with the RMA number 

on all packaging, and adequately insured, to the following address: 

Relign Corporation, 655 Campbell Technology Parkway, Suite 275, 

Campbell, CA 95008. 

14.  CUSTOMER SERVICE/TECHNICAL SUPPORT 

Contact Relign’s Customer Service for any customer or technical support.  

Call 866-608-0131 or e-mail us at 

[email protected]

Relign Corporation 

655 Campbell Technology Parkway, Suite 275 

Campbell, CA 95008, USA  

866-608-0131 

 

[email protected]

 

www.religncorp.com

 

 
 
 
© 2018 Relign Corporation. All rights reserved. 

Содержание R-10002

Страница 1: ...asis of blood vessels through its shaver blade and probe Examples of uses of the product include resection of torn knee cartilage subacromial decompression and resection of synovial tissue in other joints Contraindications The electrosurgical probe should not be used in procedures where a nonconductive irrigant is used or with patients having cardiac pacemakers or other electronic implants 4 CONTR...

Страница 2: ...ssory or device be sure to follow the instructions provided with the accessory or device 7 HOW SUPPLIED Warning The Tricera Handpiece is supplied non sterile It must be cleaned and sterilized before the first use Prior to each subsequent use it must be cleaned and sterilized The shipping box contains 1 ea Relign Tricera Handpiece 1 ea Shaver Blade RF Probe Cavity Brush Gordon Brush PN 721012 or eq...

Страница 3: ...ece from the other system components a Remove the shaver blade RF probe from the handpiece b Dispose of all used shaver blades RF probes according to hospital regulations c Disconnect the handpiece from the Relign Controller 2 Attach the soaking cap to the cable connector Caution Always install the soaking cap prior to cleaning or sterilization If moisture reaches the connection pins of the cable ...

Страница 4: ...ny additional moisture from the handpiece 10 2 STERILIZATION INSTRUCTIONS Clean and sterilize the handpiece prior to the first use and every use thereafter Caution Never sterilize the handpiece that has not been cleaned The success of the sterilization process depends on the previous state of cleaning Caution Always install the soaking cap prior to cleaning or sterilization If moisture reaches the...

Страница 5: ...ade in a sterile irrigant and activate suction while testing the handpiece 2 Run the handpiece through its various functions modes and settings to ensure it responds properly to commands Ensure that all parts move freely and that there are no loose or missing components Note any unusual sounds or vibrations and note operating speeds 3 Refer any calibration or operating difficulties to your Relign ...

Страница 6: ... term original purchaser as used in this warranty means that person or organization and its employees if applicable to whom the Tricera Handpiece was sold by Relign This warranty may not be assigned or transferred in any manner In order to make a warranty claim the original customer must obtain a Return Materials Authorization Number RMA Number and return instructions from Relign s Customer Servic...

Страница 7: ...era Handpiece 1 Shaver Blade RF Probe Cavity Brush Gordon Brush PN 721012 or equivalent 2 Fluid Channel Brush Key Surgical PN AT 12 197 or equivalent 3 Motor Shaft Brush Gordon Brush PN 499NAD ST or equivalent Figure A3 Cleaning Brushes 1 Sterilization Tray 2 Sterilization Tray Lid 3 Rubber Holders Figure A4 Optional Sterilization Tray if available 1 2 3 1 Shaver Blade Cavity 2 Motor shaft 3 Fluid...

Страница 8: ...The shaver blade does not turn The shaver blade is not inserted properly Remove the blade and reinsert it according to the Relign Tricera System instructions for directions on use of the Tricera Handpiece as part of the Relign Tricera System The handpiece will not run The handpiece is not properly connected to the controller Remove and reconnect the handpiece cable to the controller according to t...