background image

Model F1-300
300 psi (20,7 bar) Rated
Standard Response
Sprinklers

Product Description

Reliable Models F1-300 Upright, Pendent and

Recessed Pendent Sprinklers are high pressure rated

automatic sprinklers which can handle a maximum

service pressure of 300 psi (20,7 bar).

The Model F1-300 glass bulb sprinkler combines

durability with the attractive low profile of a decorative

sprinkler. Whether installed on exposed piping or below

an office ceiling, it is functional and attractive.

The Model F1 Recessed Escutcheon provides

convenient adjustment for Model F1-300 Sprinklers. The

two-piece construction makes field installation an easy

and rapid task. This also allows ceiling panels to later be

removed without shutting down the fire protection

system, thus facilitating maintenance of above ceiling

services.

The Models F1-300 Upright, Pendent and Recessed

Pendent automatic sprinklers are standard response

sprinklers which utilize a 5.0mm frangible glass bulb. The

glass bulb contains an accurately controlled amount of

special fluid hermetically sealed inside. The other

sprinkler parts are made of brass, copper or beryllium

nickel.

At normal temperatures, the glass bulb contains fluid

in both the liquid and vapor phases. The vapor phase

can be seen as a small bubble. As heat is applied, the

liquid expands, forcing the bubble smaller and smaller as

the liquid pressure increases. Continued heating forces

the liquid to push out against the bulb, causing the glass

to shatter, opening the waterway and allowing the

deflector to distribute the discharging water.

The temperature rating of the sprinkler is identified by

the color of the glass bulb.

Application

The most common applications for Model F1-300

sprinklers will be in fire protection systems for high rise

buildings or where the pressure entering the sprinkler

system is in excess of 175 psi (12 bar). The use of these

sprinklers will provide opportunity to reduce or eliminate

the need for pressure reducing valves.

Upright

Pendent

Recessed Pendent

Bulletin 155

Rev

.C

The Reliable Automatic Sprinkler Co., Inc.

525 North MacQuesten Parkway, Mount Vernon, New York 10552

Bulletin

155

Rev.

C

Sprinkler Types

• Upright

• Pendent

• Recessed Pendent

Model F1-300
Standard Response Sprinkler

Listings & Approvals

1. Listed by Underwriters Laboratories, Inc. and

Certified for Canada (cULus)

2. NYC MEA 258-93-E

UL Listing Category

Sprinklers, Automatic & Open (VNIV)

Содержание F1-300

Страница 1: ...f brass copper or beryllium nickel At normal temperatures the glass bulb contains fluid in both the liquid and vapor phases The vapor phase can be seen as a small bubble As heat is applied the liquid...

Страница 2: ...m NPT R 5 6 80 2 2 56mm R5515 17 32 20mm NPT R 8 0 115 2 4 61mm R5512 Installation Data Sprinkler Type Nominal Orifice Size Thread Size Nominal K Factor Sprinkler Height Sprinkler Identification Numbe...

Страница 3: ...sprinkler that has been painted other that factory applied or damaged in any way A stock of spare sprinklers should be maintained to allow quick replacement of damaged of operated sprinklers Prior to...

Страница 4: ...echanical sprinkler alarms Pressure gauges Electrical sprinkler alarm switches Identification signs Water flow detectors Fire department connections The equipment presented in this bulletin is to be i...

Страница 5: ...ols to fit accurately against the ceiling The fire protection system need not be shut down to adjust or remove the cover plate assembly Product Description The Reliable Model G4FR Standard Response Co...

Страница 6: ...he United States Canada and foreign countries The Reliable Automatic Sprinkler Co Inc 800 431 1588 Sales Office 800 848 6051 Sales Fax 914 668 3470 Corporate Offices www reliablesprinkler com Internet...

Страница 7: ...sprinkler that uses Reliable s push on thread off sidewallcover Thissprinklerhasthecupfactorymountedand is shipped with a protective cap that protects the 3mm frangible glass bulb during shipping and...

Страница 8: ...t be ordered separately Installation is completed by removing the protective cap and inserting the F2 Escutcheon over the collar DH80 with SWC Cover Plate Concealed Toinstallthesprinkler cuta25 8 diam...

Страница 9: ...3 Figure 1 Figure 2 Figure 3...

Страница 10: ...hout the United States Canada and foreign countries Reliable For Complete Protection Reliable offers a wide selection of sprinkler components Following are some of the many precision made Reliable pro...

Отзывы: