Parameterization
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 162 of 175
TR - ECE - BA - DGB - 0102 - 09
01/17/2019
7.8 Object 0xF6, Ethernet Link
The
Ethernet Link Object
maintains link-specific counters and status information
for an Ethernet 802.3 communications interface. The measuring system supports
exactly one instance of the Ethernet Link Object for each Ethernet IEEE 802.3
communications interface on the module. The measuring system possesses two ports
and thus two Ethernet link object instances.
7.8.1 Common Services
Service Code
Service Name
Description
0x0E
Get_Attribute_Single
Returns the contents of the specified
attribute.
0x10
Set_Attribute_Single
Modifies the contents of the specified
attribute.
7.8.2 Class specific Services
Service Code
Service Name
Description
0x4C
Get_and_Clear
Gets then clears the specified attribute
(Interface Counters or Media Counters).
7.8.3 Class Attributes
Nr. Access
Name
Data type
Attribute Description
Default
1
Get
Revision
UINT
Revision of this object
0x0003
2
Get
Max Instance UINT
Maximum instance number of an
object currently created in this class
level of the device.
0x0002
3
Get
Number of
Instances
UINT
Number of object instances
currently created at this class level
of the device.
0x0002
Table 22: Ethernet Link, Overview of the class attributes