Commissioning
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 108 of 175
TR - ECE - BA - DGB - 0102 - 09
01/17/2019
LED4: Net Status
LED status
Description
OFF
Not powered, no IP address
ON
(green) Connection established
FLASHING
(green)
No connection
ON
(red)
The device has detected that its IP address is already in use
FLASHING
(red)
One or more of the connections in which this device is the target
has timed out. This state is left only if all timed out connections are
re-established or if the device is reset.
For appropriate measures in case of error see chapter "Causes of faults and
remedies" on page 170.
5.3 MAC-Address
Already by TR-Electronic each EtherNet/IP
™ device a worldwide explicit device
identification is assigned und serves for the identification of the Ethernet node. This 6
byte long device identification is the MAC-Address and is not changeable.
The MAC-Address is divided in:
● 3 Byte Manufacturer-ID and
● 3 Byte Device-ID, current number
Normally the MAC-Address is printed on the connection hood of the device.
E.g.: “00-03-12-04-00-60”