5 Commissioning
5.1 EDS file
The EDS (electronic datasheet) contains all information on the measuring system-
specific parameters and the measuring system’s operating modes. The EDS file is
integrated using the EtherNet/IP
™ network configuration tool to correctly configure or
operate the measuring system.
The EDS file has the file name "
04710022_TR_C_SERIES_X_X.eds
".
Download:
www.tr-electronic.de/f/TR-ECE-ID-MUL-0040
5.1.1 Integration into the
Rockwell Control “RSLogix5000”
RSLogix version < 20.00:
The measuring system can be integrated only about the basic "Generic Ethernet
module".
RSLogix v
ersion ≥ 20.00:
The measuring system can be integrated directly about the device specific EDS
file.