Operation
Operating_Manual_Fan_KXE_04_en.docx
81 / 128
Operation of the fan is only permissible if the limit values of
the monitoring devices remain below that prescribed. Refer
to chapter 8.9 Monitoring devices limit values.
For values above the limit values for “disconnection”,
shut down the fan immediately and rectify the cause
of the fault. Only when the fault has been rectified
may the fan be restarted.
Operation of the fan without flow (with shut-off devices
closed at inlet and discharge) is only permissible briefly as a
start-up aid. This mode is prohibited for continuous
operation.
DANGER
Extremely high fan vibrations or bearing temperatures!
Fatalities or extremely serious injuries resulting from tipping
due to fixings of the fan becoming loose, or due to the
ejection of parts.
→ Ensure continuous monitoring of the fan condition.
→ Check functional efficiency of the monitoring devices.
→ Shut down the fan if the limit values are exceeded.
Refer to chapter 8.9.
→ Rectify the faults. Refer to chapter 11.
The control of the plant in which the fan is installed must be
configured to ensure that the fan is powered down and
switched off with the shut-off devices closed.
10. Operation