Start-up
Operating_Manual_Fan_KXE_04_en.docx
75 / 128
Regard the following points when powering up the fan:
-
Close the damper (such as throttle damper or shut-off
damper) to alleviate the power-up phase
- A sufficient level of acceleration torque must be
available throughout the entire period of the power-up
phase up to nominal speed
DANGER
Bursting of the fan, ejection of parts!
Fatalities or extremely serious injuries as a result of
exceeding the maximum speed.
→ Never exceed the maximum speed specified on the
nameplate of the fan.
Observe and record the following parameters:
Period of operation
Parameters
During power-up
Power consumption,
voltage,
vibrations,
noises
Following power-up
(without load)
Power consumption,
voltage,
vibrations,
noises
Following power-up (with
load, i.e. setting of
operating point)
Power consumption,
voltage,
vibrations,
noises,
and additionally:
bearing temperatures
temperature increase at
fan housing due to
compression of handled
gas
9.3 Powering up the fan
Table 9-1
Inspections during power-up