8.3.2 Setting the Station's IP address
*ADMIN ETHER IP <IP-Address>
This command sets the station's IP-address, i.e.:
*ADMIN ETHER IP 192.168.240.93/24 sets the station's IP-address to:
192.168.240.93 with subnet mask 255.255.255.0
NOTE: If you don't get access to the station via the network, you need to set the station's IP-
address via the serial port.
8.3.3 Setting an ADMIN address and an ADMIN password
*ADMIN SET ADDRESS <IP-Address>
*ADMIN SET ADDRESS <MAC-Address>
*ADMIN SET ADDRESS <MAC-Address> <IP-Address>
So you can set the ADMIN address (MAC- and / or IP-address) getting full access to the weather
station.
The setting is similar to *
ADMIN SET INCLUDE
, this means, you also can set ranges of addres-
ses what is not recommendable.
*ADMIN SET PASSWD 123xyz
sets the ADMIN password which is used for the ADMIN commands.
The password can contain up to 15 alpha numerical characters. No blanks and # / ! ? must be
contained in the password. The first character must not be a letter! If the password does not meet
this rules it will be rejected!
Capital and non capital letters are distinguised. (A
≠
a)!
If an ADMIN password is set this password needs to be inserted directly after ADMIN, i.e.:
*ADMIN 123myPW GET POWER
.
Also setting a new password required the old password:
*ADMIN 123myPW SET PASSWD 456myNewPW
*ADMIN GET ADDRESS
outputs the ADMIN address previously set with *ADMIN SET ADDRESS:
ADMIN ADDRESS
>MAC 90-1B-0E-23-45-67 & IP 192.168. 0. 0/16 (C0.A8.xx.xx)
If an ADMIN address is not yet set or has been deleted with ADMIN REMOVE ADDRESS, only
three minusses will be displayed:
ADMIN ADDRESS
>---